Information about the appliance
SUPRAECO W – 6 720 646 161 (2012/04)
9
3.9
Refrigerant circuit
The refrigerant circuit is a closed system in which the refrigerant R134a
circulates as a heat transfer medium.
The evaporator transfers the heat from the air to the refrigerant circuit,
and the refrigerant evaporates into a gas.
The compressor compresses the refrigerant R134a, thus increasing its
temperature.
Then the heat is transferred via a heat exchanger, also referred to as a
condenser, to the storage tank water. The refrigerant R134a condenses
in the process.
R134a flows through the expansion valve in liquid state with decreasing
pressure. Then it is routed back to the evaporator.
Fig. 6
[1]
Air fan
[2]
Evaporator
[3]
Compressor
[4]
Condenser (gas/water heat exchanger)
[5]
NTC temperature sensor (air inlet)
[6]
DHW connection
[7]
Temperature sensor aperture (data for programming unit for
solar thermal system or central heating)
[8]
Internal indirect coil
[9]
Cold water inlet
[10] Electric heating insert
[11] NTC temperature sensor (top of storage tank)
[12] DHW circulation pump
[13] NTC temperature sensor (bottom of storage tank)
[14] Dry filter
[15] Expansion valve
[16] Low-pressure pressure switch
[17] Water purge
[18] High-pressure pressure switch
[19] Magnesium anode