Operation
SUPRAECO W – 6 720 646 161 (2012/04)
22
B
Use the „+“ and „-“ keys to define the operating start schedule of the
2
nd
period.
B
Press „ok“.
Blinking display shows the operating stop schedule for the 2
nd
period.
B
Use the „+“ and „-“ keys to define the operating duration.
B
Press „ok“.
Days „1 to 5“ are now set.
Fig. 34 Start of 1st operating period for days „6 to 7“
B
Repeat the above described operations for the operating periods of
days „6 and 7“.
Completed definition of the 2
nd
operating period for days „6 and 7“
concludes the definition of the operating periods.
Fig. 35 Definition of periods
[1]
Start of 1st period
[2]
End of 1st period
[3]
Start of 2
nd
period
[4]
End of 2
nd
period
Switching off the operating period
B
Select the start schedule and end of functioning for the same time.
The operating period will be switched off.
8.5.3 „Leg“ function - automatic thermal disinfection
The „Leg“ function permits activation/deactivation of the thermal
disinfection process. This bacteria elimination process should be
performed at least once a week.
Fig. 36 „Leg“ function
Automatic activation of the „Leg“ function
B
Access the Leg function and press „ok“.
Display with blinking indication „
“ active.
B
Press „+“.
Display with blinking indication „
“ active.
B
Press „ok“.
„Leg“ function activated and blinking 1
st
day of the week.
Define the day of the week for disinfection.
B
Select the day, using the „+“ and „-“ keys.
B
Press „ok“.
Define the time of disinfection
B
Select the time, using the „+“ e „-“ keys.
B
Press „ok“.
Upon reaching a temperature of 70 °C, the device returns to the
previously selected mode.
Manual activation of the „Leg“ function
B
Access the „Leg“ function and press „ok“.
Display with blinking indication „
“ active.
B
Press „ok“.
„Leg“ function activated.
If there‘s no need for a 2nd working period.
B
Select the start schedule and end of functioning for
the same time.
6720646160-41.1V
6720646160-38.1V
1
2
3
4
The device is factory set with the function deactivated.
Activation of the disinfection mode temporarily replaces
any defined programming.
WARNING:
Beware of burns!
Hot water can cause serious burns.
B
Thermal disinfection should only be performed
outside normal working hours.
B
Warn all users of the danger of burns and the need to
perform thermal disinfection.
The disinfection process will run for a maximum period
of 24h. After this time, if a temperature of 70 °C has not
been reached (due to consumption of hot water during
the disinfection period), the device will automatically
return to the previously selected mode of functioning.
The hot water temperature is automatically set at 70 °C.
The hot water temperature is automatically set at 70 °C.
6720646160-17.1V