Table 103: Details of a Virtual Chassis Member Switch
Example
Details
EX3300
Model number of the member switch
ID 2
NOTE:
If the member switch is not provisioned, the serial
number of the switch is displayed instead of its ID.
Assigned ID that applies to the entire Virtual Chassis
configuration
Master
Possible roles are: Master, Backup, or Linecard
Role of the member switch
Prsnt
Possible statuses are: Prsnt, NotPrsnt, Inactive, or Unprvsnd
Status of the member switch
The status of the member switch is displayed on the image of the switch. If the member switch appears
dimmed, it means the switch is not present, is inactive, or is not provisioned in the Virtual Chassis. If the
member switch does not appear dimmed, it means the switch is present and is active.
describes the possible status of a member switch.
Table 104: Status of a Member Switch in a Virtual Chassis
It means the member switch
It appears as
If the member switch is
Has established physical and logical connections with
Virtual Chassis member switches.
Prsnt
Present
Has been disconnected from the existing Virtual Chassis.
dimmed and
NotPrsnt
Not present
Has established physical connections, but is unable to
establish logical connections.
dimmed and
Inactive
Inactive
Cannot synchronize with the existing preprovisioned Virtual
Chassis.
dimmed and
Unprvsnd
Not provisioned
Click Rear View for a graphical view of the rear panel of the switch.
539
Содержание QFX3500
Страница 1: ...Virtual Chassis Fabric Hardware Documentation Published 2020 11 06...
Страница 225: ...Translation The emitted sound pressure is below 70 dB A per EN ISO 7779 201...
Страница 229: ...205...
Страница 238: ...Unterminated Fiber Optic Cable Warning 214...
Страница 246: ...Restricted Access Warning 222...
Страница 249: ...225...
Страница 257: ...Jewelry Removal Warning 233...
Страница 260: ...Operating Temperature Warning 236...
Страница 271: ...DC Power Disconnection Warning 247...
Страница 275: ...DC Power Wiring Sequence Warning 251...
Страница 278: ...DC Power Wiring Terminations Warning 254...
Страница 408: ...Understanding Virtual Chassis Fabric Configuration 4 Understanding Virtual Chassis Fabric Components 384...
Страница 410: ...Figure 130 All QFX5110 VCF g050760 Figure 131 QFX5110 VCF with QFX5100 24Q Leaf Devices 386...
Страница 412: ...Figure 132 QFX5100 24Q as a Leaf Device in a QFX5110 VCF 388...
Страница 565: ...Table 105 System Information continued Description Field Inventory details 541...
Страница 602: ...6 PART Troubleshooting Restoring Junos OS 579 Returning Hardware 586 Alarms and System Log Messages 623...