Figure 75: Holding an FPC Horizontally
Related
Documentation
Holding an M40e FPC Overview on page 133
•
•
FPC LEDs and Controls on the M40e Craft Interface on page 38
•
M40e FPCs Supported on page 17
•
Replacing an FPC in an M40e Router on page 191
•
M40e Flexible PIC Concentrators (FPCs) Description on page 13
Storing an M40e FPC
When not installed in the routing platforms, FPCs must be either stored in the container
in which a spare FPC is shipped or stored horizontally and component-side up on a flat,
stable surface.
When you store an FPC on a horizontal surface or in the shipping container, always place
it inside an antistatic bag. Because the FPC is heavy and because antistatic bags are
fragile, inserting the FPC into the bag is easier with two people. To do this, one person
holds the FPC in the horizontal position with the faceplate facing the body, and the other
person slides the opening of the bag over the FPC connector edge. If you must insert the
FPC into a bag by yourself, first lay the FPC horizontally on a flat, stable surface,
component-side up. Orient the FPC with the faceplate facing you. Carefully insert the
FPC connector edge into the opening of the bag, and pull the bag toward you to cover
the FPC.
CAUTION:
To prevent damage when storing FPCs, observe the following
precautions:
•
Never lay an FPC component-side down.