Action
The router can have up to eight Flexible PIC Concentrators (FPCs) mounted vertically in
the FPC card cage at the front of the chassis, as shown in “M40e Chassis Description”
on page 8. To maintain FPCs, regularly:
•
Check the LCD on the craft interface and the LEDs on the craft interface directly above
each FPC slot. The green LED labeled
OK
lights steadily when an FPC is functioning
normally. For more information, see “FPC LEDs and Controls on the M40e Craft
Interface” on page 38.
•
Issue the CLI
show chassis fpc
command to check the status of installed FPCs. As
shown in the sample output, the value
Online
in the column labeled
State
indicates
that the FPC is functioning normally:
user@host>
show chassis fpc
Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
0 Online 37 4 0 32 2 40
1 Empty
2 Offline -- FPC not supported on platform --
3 Empty
4 Online 34 1 0 32 1 40
5 Online 35 4 0 32 2 40
6 Online 39 4 0 32 1 39
7 Empty
Related
Documentation
FPC LEDs and Controls on the M40e Craft Interface on page 38
•
•
M40e FPCs Supported on page 17
•
Holding an M40e FPC Overview on page 133
•
M40e Flexible PIC Concentrators (FPCs) Description on page 13
Holding and Storing M40e FPCs
•
Holding an M40e FPC Overview on page 133
•
Holding an M40e FPC Vertically on page 136
•
Holding an M40e FPC Horizontally on page 137
•
Storing an M40e FPC on page 138
Holding an M40e FPC Overview
CAUTION:
To prevent damage when handling or carrying FPCs, observe the
following precautions.
NOTE:
An FPC configured with PICs installed can weigh as much as 15 lb
(6.8 kg). Be prepared to accept the full weight of the FPC as you lift it.