Figure 11: BTI7802 1-Slot/2-Slot Chassis DC Power Entry Module
If a seated DC PEM is not connected to a power feed, but the chassis is otherwise powered
(by the other PEM), the following occurs:
•
The unpowered DC PEM is shown in inventory.
•
The red LED on the unpowered DC PEM is illuminated.
•
A
powerAbsent
alarm is raised for the unpowered DC PEM.
BTI7802 DC PEM Specifications
Table 20: BTI7802 1-Slot/2-Slot Chassis DC Power Entry Module (BT8A78PEM1-DC) Specifications
Specification
Item
Physical Dimensions
85 mm
3.35 in
Width
40.5 mm
1.59 in
Height
305 mm
12.00 in
Depth
0.7 kg
1.60 lb
Weight
99.9% efficient (maximum 20W)
Power Consumption (40°
ambient)
NOTE:
Before using for
planning or implementation
purposes, contact Juniper
Networks Support to confirm
the power consumption values.
1000 W
Power Capacity
49
Copyright © 2019, Juniper Networks, Inc.
Chapter 2: BTI7800 Series Chassis
Содержание BT8A78CH1
Страница 8: ...Copyright 2019 Juniper Networks Inc viii BTI7800 Series Hardware Overview and Installation Guide...
Страница 14: ...Copyright 2019 Juniper Networks Inc xiv BTI7800 Series Hardware Overview and Installation Guide...
Страница 20: ...Copyright 2019 Juniper Networks Inc xx BTI7800 Series Hardware Overview and Installation Guide...
Страница 68: ...Copyright 2019 Juniper Networks Inc 68 BTI7800 Series Hardware Overview and Installation Guide...
Страница 74: ...Copyright 2019 Juniper Networks Inc 74 BTI7800 Series Hardware Overview and Installation Guide...
Страница 99: ...99 Copyright 2019 Juniper Networks Inc Chapter 4 Installing the BTI7800 Series Chassis...
Страница 178: ...Copyright 2019 Juniper Networks Inc 178 BTI7800 Series Hardware Overview and Installation Guide...
Страница 210: ...Copyright 2019 Juniper Networks Inc 210 BTI7800 Series Hardware Overview and Installation Guide...