Selected for : 13 days, 23 hours, 14 minutes, 23 seconds
Selected since : 2012-10-29 18:29:29 EDT
SEE ALSO
Clocking Ports Specifications on the ACX2000 and the ACX2100 Router | 89
Connecting ACX2000 or ACX2100 Routers to an External Alarm-Reporting
Device
To connect the router to external alarm-reporting devices, attach wires to the ALARM relay contacts on
the front panel of the router. A system condition that triggers the red or yellow alarm on the router also
activates the corresponding alarm relay contact.
The terminal blocks that plug into the alarm relay contacts are supplied with the router. They accept wire
of any gauge between 20 AWG and 14 AWG (0.52 and 2.08 mm
2
), which is not provided. Use the gauge
of wire appropriate for the external device you are connecting.
To connect an external device to an alarm relay contact:
1. Prepare the required length of wire with gauge between 8 AWG and 14 AWG (0.08 and 2.08 mm
2
.
2. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to
one of the ESD points on the chassis.
3. While the terminal block is not plugged into the relay contact, use a 2.5-mm flat-blade screwdriver to
loosen the small screws on its side. With the small screws on its side facing left, insert wires into the
slots in the front of the block based on the wiring for the external device. Tighten the screws to secure
the wire.
4. Orient the terminal block according to the labels to the left of the appropriate relay contact (NC means
“normally closed, C means “common,” and (NO means “normally open”).
5. Plug the terminal block into the relay contact and use a 2.5-mm flat-blade screwdriver to tighten the
screws on the face of the block.
6. Attach the other end of the wires to the external device.
110
Содержание ACX2000
Страница 1: ...ACX2000 and ACX2100 Universal Metro Router Hardware Guide Published 2020 09 07 ...
Страница 91: ...Front Panel of an ACX2000 Router 47 LEDs on ACX2000 and ACX2100 Routers 57 91 ...
Страница 116: ...4 CHAPTER Maintaining Components Maintaining ACX2000 and ACX2100 Components 117 ...
Страница 125: ...5 CHAPTER Troubleshooting Hardware Troubleshooting ACX2000 and ACX2100 126 ...
Страница 139: ...139 ...
Страница 144: ...Restricted Access Warning 144 ...
Страница 148: ...148 ...
Страница 161: ...Jewelry Removal Warning 161 ...
Страница 164: ...Operating Temperature Warning 164 ...
Страница 174: ...DC Power Disconnection Warning 174 ...
Страница 178: ...DC Power Wiring Sequence Warning 178 ...
Страница 181: ...DC Power Wiring Terminations Warning 181 ...