These are must know before you start.
1.
DO NOT try to siphon water into the pump, DO NOT install the pump above the reservoir
or it will not prime properly 100% of the time. Even if it works, it's not the way to do it.
Install the reservoir bulkhead with 1-2ft leading to the pump. Always gravity feed water
to the pump. Read more about a proper design below.
2.
DO NOT force fittings apart or rip tubing out of the fitting. Very easy to take them apart,
press on the collet and gently pull. They will not come out simply by pulling apart. See
this video if you don’t know how
http://www.mistking.com/RemovingTubing.html
3.
Don’t ever unscrew the tip of the nozzle when you receive the system. We test them
twice so they come fully functional. If it’s not working, it’s probably something with the
setup and not the misting assembly. Touching the delicate cone in the middle of the
misting nozzle will alter the spray pattern and possibly damage the spray. Be careful and
don’t touch the center !
4.
Remember that misting assemblies are for high pressure application and have a check
valve built in. You cannot blow through the nozzle. Even if you could blow through it, the
flow is so little you would not feel it.