D*AP8 MAP
40
Setup GUI – INTERFACES – 8 Ch Analog Out Interface
Analog Output Calibration
sets the factor for D/A conversion
(dBu) (level for digital 0 dBFS)
ANLx (dBu)
[0.0 … 15.0 … 24.0]
output level for output "x" at 0dBFS.
The default setting of 15.0dBu correlates to the 6dBu = -9dBFS
conversion.
Setup GUI – INTERFACES – 4 Ch Analog I/O Interface
An additional analog interface can be installed in the Interface slot.
It provides 4 additional analog line inputs and outputs on a 25pin D-Sub connector:
Enable Relay Bypass
[ON / OFF]
(All Channels)
Power fail bypass relay that may be activated from the GUI
Analog Input Calibration
[0 … 15.0 … 24.0]
(dBu)
(level for digital 0 dBFS)
A/D conversion parameter. It defines the analog input level in dBu to
reach a digital full scale signal.
Analog Output Calibration
[0 … 15.0 … 24]
(dBu)
(level for digital 0 dBFS)
D/A conversion parameter. It defines the analog output level in dBU
for a digital full scale signal.