D*AP8 MAP
18
Authentication
To prevent non authorized people from
changing D*AP8 MAP settings the
administrator may assign passwords for
either the admin and/or an operator
(same applies for talent/artist). While the admin is allowed to set everything,
an operator is just allowed to load presets. Parameters will be reset if there
was an attempt from the operator to change it.
Enable
[enable / disable]
The administrator may turn authentication off.
Change Password for [admin / operator]
Select which password you will set / change
Password
key in a password
Default passwords are: admin (for admin) and operator (for operator).
Repeat
repeat that password
Important Note! The authentication may be enabled / disabled from the console interface via USB
connection as well (see page 8 "1: Manage Password") but also via Telnet! If you have higher security
demands you should turn the Telnet server off. Authentication will be turned off and passwords will be reset if
one initializes the device to factory default (see Reboot - page 19, INIT/RESET rear button - page 4).
If there was an authentication failure, the admin will be notified
on next proper login about such conditions The pop up appears
as often as a login failed. It shows the IP address of the device
that caused the authentication failure.
After a correct login the status "who" (e.g. admin)
and a <Log Out> button are available from the GUI:
Network
IP address setup, see above:
getting started – IP setup of the MAP
–
via web browser
IP Address
The address of your choice – default [10.110.xxx.yyy]
Netmask
The net mask of your network – default [255.255.0.0]
Gateway
The optional gateway address – default [0.0.0.0]
Transmit Metering Data
[ON / OFF]
Metering data will be streamed via UDP protocol. In order to receive such
data by external applications and the GUI, you must enable it.
Service Options
Maintenance Interface [ON / OFF]
via RPC
For administrative use to enable communication with factory tools.
Telnet Server
[ON / OFF]
Enables a telnet server to connect to the consol interface via
TCP (port 23). You must be aware about the security risks if you do that
over the internet!
Diagnostics
<get diagnostics file>
It is a duplication of the soft button from the System Status pane.