D*AP8
85
Setup GUI
–
MEASUREMENT
– Loudness
The
D*AP8 LM
offers a sophisticated loudness measurement tool for the input and output of the
program path of the device. The three control buttons
<pause>
,
<reset>
,
<reset max>
may be used to
manually control the actual measurement.
Loudness Mode
setting from AUDIO PROCESSOR > Setup > Loudness Mode
Current Measurement
[hh:mm:ss]
Time elapsed since measurement started (excluding pauses)
Integrated Loudness (LUFS)
Loudness Range (LU)
Dialnorm
-70.0 indicates that no speech has been detected. If it is
activated in the setup but no speech is recognized by the
algorithm in this case, the background of the display box turns
yellowish.
Short-Term Loudness (LUFS)
numeric and convenient bar graph display
Momentary Loudness (LUFS)
convenient bar graph display
Short Term Max (LUFS)
Momentary Max (LUFS)
True Peak Max (dBTP)
Recent Measurement
same parameters as current measurement
Integration time (hh:mm:ss)
Total time of the recent measurement
Important Note!
The measures of the parameters above depend on the loudness mode selected at
AUDIO PROCESSOR > Setup pane.
The measurement data may also be streamed to the PC based
J*AM
(Junger Application Manager).
The
J*AM
is a graph display and logging tool that one can download from the
Jungeraudio.com web
site. To perform loudness measurement and loudness logging one must buy a hardware (USB) dongle.