D*AP8
20
Sync Source Information
You will get detailed information about the measured rates of possible sync sources
System Clock
Sample Rate
[Follow Source / 44.1 / 48]
Fallback Sample Rate
[44.1 / 48]
Fallback Video rate
[25 / 29,97 / 30]
Sync Source Priorit
y
Choice 1 – 4
[OFF / Internal / Sync-In WCLK / Sync-In AES /
Interface 1 SDI I/O (if fitted) / Sync-In Black Burst/Tri-Level]
Fallback on Sync Error:
[Internal]
If the selected sync source is not available the next source will be
selected. If none of the pre selected sync sources is not available,
the source will fall back to the internal clock oscillator.
AES Select
[Sync-In AES / Input AES 1/2 BNC … AES 7/8 BNC]
Select from which physical input the AES sync must be taken.
Accept SDI Generator
[ON / OFF]
For rare application you may use the SDI generator (if an SDI I/O
interface is installed) as the sync source. In this case downstream
equipment must be synchronized to the
D*AP8
.
See
INTERFACES > SDI I/O interface > Setup
for details
Important note!
It is not possible to gen lock the SDI generator. The generator will run on its own
internal 27MHz crystal clock.
Video Sync Shift
For applications like Dolby E encoding it might be necessary to
move the timing reference point.
Offset (lines)
[-1023 … 0 … 1023]
The number of lines which the reference point can be moved in
either direction.
Setup GUI – SYSTEM – Remote Access –
X*AP Remote
The
X*AP
can control multiple
D*AP8s
one by one and a single
D*AP8
may be controlled from multiple
X*AP
s. This requires a flexible remote concept that allows you to recall pre-set configurations via the
X*AP
panel or via the
Mobile UI
. You can control pre-settings of the
EVENTS
system via remote access from the
X*AP
remote panel or from a
Mobile
UI
on a tablet, a smart phone or even via a browser session from any
PC in the network.
To better understand the possibilities of these settings it is recommended you study the comprehensive
EVENTS
system of the
D*AP8
.