D*AP8
4
Hardware concept
The
D*AP8 editions
are based on the
D*AP8 device
that carries all relevant connectors.
An optional
X*AP RM
1
remote panel can be used to control the
D*AP8
.
D*AP8
front panel view
The front panel of the
D*AP8
has a 3 line status display and two hidden touch buttons ~ 2.5cm left of the
display.
Button 1
= Home will switch back to the power up display no matter which display level you are in.
Button 2
controls the multi level display:
Level 1
Power up display [Device type, firmware version]
Level 2
Status
[OK / Error] / Device Name / IP address
Level 3
IN peak meter (10x)
Level 4
OUT peak meter (10x)
The total number of display levels depends on the number of programs. For 5.1 + 2 mode (2 programs) we
will have 4 more levels while for 4 x 2 (4 programs) we will have 8 more levels:
Level 5 - 8
Program 1 - 4 Out - short term loudness
Level 9 - 12
Program 1 - 4 Out - integrated loudness and integration time
The measures of the loudness displays depend on the setup of the respective loudness mode
(see AUDIO PROCESSOR > SETUP > Loudness Mode).
Display background
Green = device status OK
color
Red
= device status ERROR
X*AP RM
1
front panel view
The
X*AP RM
1
remote panel is powered by POE (Power Over Ethernet) or an external wall plug PS and
designed to control multiple
D*AP8 unit
s one at a time. For details of operation see extra manual
"XAP_manual_EN_140328.pdf" or later.