2  Safety instructions

 

f

Treat alarm and alert tones from the 

radio smoke alarm device as a priority.

 

f

Use the device only as intended and in 

a technically perfect condition.

Battery replacement

If a battery replacement is required, please 

send the device to ALBRECHT JUNG GMBH 

& CO. KG. Our specia-

lists will then undertake 

the battery replacement 

for you. This work will be 

invoiced. Never open the 

device yourself to change 

the batteries. This would 

void any warranty claims.

2.3  Improper use

The device must not be used for the following 

purposes:

 

Any use which is not expressly 

described as being permitted in this 

operating manual 

2.1  Presentation and structure of 

warning labels 

The warning labels are action-oriented; they 

are structured and graded as follows:

CAUTION

Type and source of the danger!

Explanation about the type and source.

 

f

Measures to avert the danger.

CAUTION

Potential minor injuries, material or 

environmental damage.

2.2  Proper and intended use

The device may only be used for the following 

purposes:

 

Addition to a FRWM radio group 

to an external interface  

(alarm output)

 

Expansion of a FRWM radio 

group to include an alarm input 

When using the FRWM-AR, plea-

se note the following:

Содержание FRWM-AR

Страница 1: ...FRWM AR Alarmrelais mit potentialfreiem Eingang Alarm relay with oating input Betriebsanleitung Operating manual ALBRECHT JUNG GMBH CO KG Volmestra e 1 58579 Schalksm hle www jung de...

Страница 2: ...l Specifications 38 EN DE Inhaltsverzeichnis 1 Hinweise zur Betriebsanleitung 03 2 Sicherheitshinweise 06 3 bersicht 09 4 Inbetriebnahme 11 5 Konnektivit t 14 6 Verbindungstest 14 7 Auslieferungszusta...

Страница 3: ...ds and downtime or a loss of warranty claims It is absolutely necessary that the operating manual is read and understood For better readability the FRWM AR alarm relay is hereinafter referred to as FR...

Страница 4: ...particularly the rights of duplication distribution and translation No part of this operating manual may be repro duced in any form or processed duplicated or disseminated using electronic systems wi...

Страница 5: ...se quential damages including but not limited to resulting loss of revenue loss of profits restrictions of the use of software hardware loss or recovery of data cost of substitute equipment downtime d...

Страница 6: ...Improper use The device must not be used for the following purposes Any use which is not expressly described as being permitted in this operating manual 2 1 Presentation and structure of warning labe...

Страница 7: ...ures by topic and apply at all times General The devices are subject to strict quality cont rols during production In addition a function test is performed before delivery Nevertheless unexpected malf...

Страница 8: ...Risk of corrosion and burns Improper handling of the batteries can cause them to leak explode or inflame This can result in chemical burns and other burn injuries f f Do not charge the batteries f f...

Страница 9: ...e Status LED the Buzzer the relay itself Depending on which end device or fire alarm controller is connected to the FRWM AR these get also activated via triggering the alarmout put of the relay If the...

Страница 10: ...1 2 COM ground 1 3 NO normally opened 2 Input A maximum voltage of 24 V can be connected to the potential free alarm input The switching level is 1 6 V 3 Status LED Displays various events 4 Buzzer A...

Страница 11: ...n To subsequently change the connecti on state a new installation of the radio group is required 3 3 Application example 1 Trigger button One possible way to use the alarm input of your FRWM AR is the...

Страница 12: ...ted or the voltage drops below the switching threshold of 1 6 V Connection variants 1 Input open To activate this variant you do not need to take any further steps before integra ting into the radio g...

Страница 13: ...arm 4 3 Integrating into a radio group The FRWM AR cannot be the master in a radio group Therefore to integrate the FRWM AR at least one FRWM must be in learning mode Perform the following steps to in...

Страница 14: ...o connection to the FRWM AR 1 To start the connection test press and hold the test stop button on a FRWM for approx 12 seconds 2 All the participants in the radio group will now produce a signal one a...

Страница 15: ...ellow interval signal Finally a quickly flashing yellow interval signal 2 Now release the button 3 The Status LED lights up green briefly 5 5 The device is now in the default status The default status...

Страница 16: ...p has been lost the FRWM AR as well as all other connected FRWMs produces a triple beep at regular intervals You can therefore check which group parti cipant is not producing a signal tone and is ther...

Страница 17: ...icipant integrated into the radio group Possible faults when integrating into the radio group All faults are indicated by the Status LED flas hing red briefly Possible fault causes Radio range A possi...

Страница 18: ...er please observe the following f f Do not throw or drop the package 10 3 Storage If you want to store the device for a longer period of time please observe the following 1 Ensure for dry ambient cond...

Страница 19: ...er form a visual inspection f Ensure that the device is not damaged 12 2 Cleaning Observe the following when cleaning f Clean the device with care e g with a damp cloth 13 Waste disposal This product...

Страница 20: ...ngle wire between 0 5 and 2 5 mm Radio frequency 868 3 MHz Ambient temperature 5 35 C Operating manual FRWM AR Alarm relay 38 EN 14 Accessories spare parts and service 14 1 Accessories FRWM IP GATE ga...

Страница 21: ...39 Platz f r Notizen Place for notes DE EN...

Страница 22: ...ALBRECHT JUNG GMBH CO KG Stand der Betriebsanleitung 2018 02 Revision of the operating manual 2018 02 Impressum ALBRECHT JUNG GMBH CO KG Volmestra e 1 58579 Schalksm hle Deutschland Germany...

Отзывы: