eNet radio dimming actuator 1-gang mini

Cause 2: overheating protection has tripped.

Disconnect dimmer from mains, also switch associated off circuit breakers.
HV-LED phase cut-off: Reduce the connected load. Exchange lamps for another type.
HV-LED phase cut-on: Reduce the connected load. Check operation in the "HV-LED trail-
ing edge phase control" setting. Exchange lamps for another type.
Let dimmer cool down for at least 15 minutes. Check installation situation, ensure cooling,
e.g. provide distance from surrounding devices.
Switch circuit breakers and dimmer on again.

Cause 3: Surge protection has triggered.

HV-LED trailing edge phase control: Check operation in the "HV-LED leading edge phase
control" setting, reduce connected load as well if necessary.
Exchange lamps for another type.

Cause 4: short-circuit protection has tripped.

Switch off the mains supply.
Eliminate short-circuit.
Switch circuit breakers and dimmer on again.

Short-circuit protection is not based on a conventional fuse, no metallic separation of the
operational current.

Cause 5: load failure.

Check load, replace lamp. For inductive transformers, check primary fuse and replace if
necessary.

Lamps flicker or buzz, proper dimming not possible, device buzzes

Cause 1: Incorrect operating mode set.

Check connected lamps. Correct the set operating mode.

Cause 2: Dimmer is connected without neutral conductor.

Connect neutral conductor if possible.
Exchange lamps.

LED lamp is dimly lit when dimmer is switched off

Cause: LED lamp is not optimally suited for this dimmer.

Use a compensation module, see accessories.
Use another type of LED lamp or an LED lamp of another manufacturer.

8

Accessories

eNet server for rail mounting

Art. no. ENET-SERVER

Mounting adapter for mini housing

Art. no. FM-EBG

Amplifier LED

Art. no. ULZ1755REG

Compensation module LED

Art. no. KMLED230U

9

Conformity

Albrecht Jung GmbH & Co. KG hereby declares that the radio system type art. no.
FMUD20250UP meets the directive 2014/53/EU. You can find the full article number on the
device. The complete text of the EU Declaration of Conformity is available under the Internet
address: www.jung.de/ce

10 Warranty

The warranty is provided in accordance with statutory requirements via the specialist trade.

15 / 16

82580733

14.10.2019

J0082580733

Содержание FM J 50700 UP

Страница 1: ...ty transformers ac cording to EN 61558 2 6 may be used These instructions are an integral part of the product and must remain with the end customer 2 Intended use Switching and dimming of lighting Ope...

Страница 2: ...er operation and signalling could vary from what is de scribed here 4 Information for electrically skilled persons 4 1 Fitting and electrical connection DANGER Mortal danger of electric shock Before c...

Страница 3: ...nsformers for halogen or LED lamps HV LED leading edge phase control Setting for incandescent lamps HV halogen lamps elec tronic transformers with halogen or LED lamps that can be dimmed according to...

Страница 4: ...than 4 seconds The status LED 4 flashes after 3 seconds The actuator is in programming mode for approx 1 minute Switch radio transmitter to programming mode see radio transmitter instructions Trigger...

Страница 5: ...for approx 5 seconds The actuator is reset to default setting Setting the minimum brightness The minimum brightness can be set within a range of approx 1 67 if e g the light flickers at low brightnes...

Страница 6: ...dissipation Operate inductive transformers with at least 85 nominal load For ohmic inductive mixed load maximum 50 proportion of ohmic load Otherwise in correct calibration of the dimmer may result P...

Страница 7: ...smitters and the Prog button are ignored Continuous off The output switches to con tinuously Off All operations of radio transmitters and the Prog button are ignored Advanced device settings Parameter...

Страница 8: ...on after a delay Repeated switch on commands restart the delay time If the load has not yet been switched on due to the delay when a switch off com mand comes then the load will remain off Note The s...

Страница 9: ...r remain on perman ently but only for the length of the run on time The run on time is restarted if actuation is repeated This parameter is directly connected to the Manual switch off of run on time p...

Страница 10: ...l LED trailing edge phase con trol Leading edge phase control Trailing edge phase control Basic setting Universal Specifies the dimming prin ciple for the selected output Universal Automatic calibrati...

Страница 11: ...value is above the set maximum brightness or below the minimum bright ness then the system will switch to the appropriate limit value Behaviour after the end of the disabling function On Off no chang...

Страница 12: ...Basic setting 2 Specifies the priority for recall ing and removing a scene of type Restraint for the channel Activate forced operation brightness value 0 100 Basic setting 100 Defines the behaviour o...

Страница 13: ...n is 0 Switch off brightness over shoot On Off Basic setting On Allows automatic switch off according to the brightness If the parameter is On then the light controller switches off automatically when...

Страница 14: ...Check manufacturer s instructions Exchange lamps for another type Cause 2 Dimming principle and lamps do not optimally match Check operation in another dimming principle reduce connected load as well...

Страница 15: ...current Cause 5 load failure Check load replace lamp For inductive transformers check primary fuse and replace if necessary Lamps flicker or buzz proper dimming not possible device buzzes Cause 1 Inco...

Страница 16: ...dimming actuator 1 gang mini ALBRECHT JUNG GMBH CO KG Volmestra e 1 58579 Schalksm hle GERMANY Telefon 49 2355 806 0 Telefax 49 2355 806 204 kundencenter jung de www jung de 16 16 82580733 14 10 2019...