eNet radio dimming actuator 1-gang mini

Parameters

Setting options, Basic setting

Explanations

dimming principle. Connection
of incandescent lamps, HV
halogen lamps, dimmable in-
ductive transformers for halo-
gen or LED lamps.

Trailing edge phase control
Dimming principle, trailing
edge phase control. Connec-
tion of incandescent lamps,
HV halogen lamps, Tronic
transformers for halogen or
LED lamps.

Behaviour on voltage return

On
Off
Last value
Configured brightness
Basic setting: Off

Defines the behaviour of the
output after voltage return.

Brightness on voltage return

0...100 %
Basic setting: 100 %

Brightness value, set by the
output after voltage return
(mains voltage). (Only visible
when the parameter "Beha-
viour on voltage return" is set
to "Configured brightness")
Note: If the value is above the
set maximum brightness or
below the minimum bright-
ness, then the system will
switch to the appropriate limit
value.

Behaviour after the end of the
disabling function

On
Off
no change
Last value
Basic setting: No change

Behaviour of the output when
a block is removed.

Manual saving of the scene
values

On, Off
Basic setting: On

Disables the saving of the cur-
rent brightness value as scene
value in an actuator for a com-
mand via a transmitter.

Switch-off warning

On, Off
Basic setting: Off

If the switch-off warning is act-
ive, then, during switch-off, the
system dims to minimum
brightness within 30 seconds
and only then switches off. If
the parameter "Dim down
ramp" is configured as longer
than 30 s, then the length of
the dim down ramp is applied.
If, during the dim down opera-
tion, another command is
given, e.g. switch on or scene
recall, then the switch-off
warning stops and the com-
mand is executed. A switch-off

11 / 16

82580733

14.10.2019

J0082580733

Содержание FM J 50700 UP

Страница 1: ...ty transformers ac cording to EN 61558 2 6 may be used These instructions are an integral part of the product and must remain with the end customer 2 Intended use Switching and dimming of lighting Ope...

Страница 2: ...er operation and signalling could vary from what is de scribed here 4 Information for electrically skilled persons 4 1 Fitting and electrical connection DANGER Mortal danger of electric shock Before c...

Страница 3: ...nsformers for halogen or LED lamps HV LED leading edge phase control Setting for incandescent lamps HV halogen lamps elec tronic transformers with halogen or LED lamps that can be dimmed according to...

Страница 4: ...than 4 seconds The status LED 4 flashes after 3 seconds The actuator is in programming mode for approx 1 minute Switch radio transmitter to programming mode see radio transmitter instructions Trigger...

Страница 5: ...for approx 5 seconds The actuator is reset to default setting Setting the minimum brightness The minimum brightness can be set within a range of approx 1 67 if e g the light flickers at low brightnes...

Страница 6: ...dissipation Operate inductive transformers with at least 85 nominal load For ohmic inductive mixed load maximum 50 proportion of ohmic load Otherwise in correct calibration of the dimmer may result P...

Страница 7: ...smitters and the Prog button are ignored Continuous off The output switches to con tinuously Off All operations of radio transmitters and the Prog button are ignored Advanced device settings Parameter...

Страница 8: ...on after a delay Repeated switch on commands restart the delay time If the load has not yet been switched on due to the delay when a switch off com mand comes then the load will remain off Note The s...

Страница 9: ...r remain on perman ently but only for the length of the run on time The run on time is restarted if actuation is repeated This parameter is directly connected to the Manual switch off of run on time p...

Страница 10: ...l LED trailing edge phase con trol Leading edge phase control Trailing edge phase control Basic setting Universal Specifies the dimming prin ciple for the selected output Universal Automatic calibrati...

Страница 11: ...value is above the set maximum brightness or below the minimum bright ness then the system will switch to the appropriate limit value Behaviour after the end of the disabling function On Off no chang...

Страница 12: ...Basic setting 2 Specifies the priority for recall ing and removing a scene of type Restraint for the channel Activate forced operation brightness value 0 100 Basic setting 100 Defines the behaviour o...

Страница 13: ...n is 0 Switch off brightness over shoot On Off Basic setting On Allows automatic switch off according to the brightness If the parameter is On then the light controller switches off automatically when...

Страница 14: ...Check manufacturer s instructions Exchange lamps for another type Cause 2 Dimming principle and lamps do not optimally match Check operation in another dimming principle reduce connected load as well...

Страница 15: ...current Cause 5 load failure Check load replace lamp For inductive transformers check primary fuse and replace if necessary Lamps flicker or buzz proper dimming not possible device buzzes Cause 1 Inco...

Страница 16: ...dimming actuator 1 gang mini ALBRECHT JUNG GMBH CO KG Volmestra e 1 58579 Schalksm hle GERMANY Telefon 49 2355 806 0 Telefax 49 2355 806 204 kundencenter jung de www jung de 16 16 82580733 14 10 2019...