eNet radio dimming actuator 1-gang mini

Parameters

Setting options, Basic setting

Explanations

%, then the system dims to
the set minimum brightness
when the hotel function is ac-
tivated.

Information window

In the Information window, the load can be controlled and the information about the device can
be displays.

Channel control/channel information

Display value

Explanations

Current dimming value

The load can be dimmed using the slider or a
brightness value entry.

Load state

The load can be switched on or off.

Restraint

Display of forced position status.

Operating hours

Display of the operating hours since the last
restart in the Settings window Einstellungen.

Display dimming principle

Display of the used dimming principle.

7

Troubleshooting

Connected LED lamps or compact fluorescent lamps switch off in the lowest dimming position
or flicker

The set minimum brightness is too low.
Increase minimum brightness.

Connected LED lamps or compact fluorescent lamps flicker

Cause 1: Lamps are not dimmable.

Check manufacturer's instructions.
Exchange lamps for another type.

Cause 2: Dimming principle and lamps do not optimally match.

Check operation in another dimming principle, reduce connected load as well if neces-
sary.

Connected LED lamps or compact fluorescent lamps in the lowest dimming position are too
bright; dimming range is too small

Cause 1: The set minimum brightness is too high.

Reduce minimum brightness.

Cause 2: HV-LED trailing edge phase control dimming principle does not optimally match the
connected HV-LED lamps.

Check operation in the "HV-LED leading edge phase control" setting, reduce connected
load as well if necessary.
Exchange lamps for another type.

Dimmer has switched off, status LED (3) flashes 3 times at intervals of 1 second

Cause 1: Operating mode switch (2) was set to another dimming principle.

The dimming principle was accidentally adjusted: Reset the original dimming principle on
the operating mode switch (see section 5.1. Mounting and Electrical Connection).
The dimming principle was intentionally adjusted: Check whether the dimming principle
matches the connected load. Switch mains voltage off and on again, the dimmer assumes
the new setting.

14 / 16

82580733

14.10.2019

J0082580733

Содержание FM J 50700 UP

Страница 1: ...ty transformers ac cording to EN 61558 2 6 may be used These instructions are an integral part of the product and must remain with the end customer 2 Intended use Switching and dimming of lighting Ope...

Страница 2: ...er operation and signalling could vary from what is de scribed here 4 Information for electrically skilled persons 4 1 Fitting and electrical connection DANGER Mortal danger of electric shock Before c...

Страница 3: ...nsformers for halogen or LED lamps HV LED leading edge phase control Setting for incandescent lamps HV halogen lamps elec tronic transformers with halogen or LED lamps that can be dimmed according to...

Страница 4: ...than 4 seconds The status LED 4 flashes after 3 seconds The actuator is in programming mode for approx 1 minute Switch radio transmitter to programming mode see radio transmitter instructions Trigger...

Страница 5: ...for approx 5 seconds The actuator is reset to default setting Setting the minimum brightness The minimum brightness can be set within a range of approx 1 67 if e g the light flickers at low brightnes...

Страница 6: ...dissipation Operate inductive transformers with at least 85 nominal load For ohmic inductive mixed load maximum 50 proportion of ohmic load Otherwise in correct calibration of the dimmer may result P...

Страница 7: ...smitters and the Prog button are ignored Continuous off The output switches to con tinuously Off All operations of radio transmitters and the Prog button are ignored Advanced device settings Parameter...

Страница 8: ...on after a delay Repeated switch on commands restart the delay time If the load has not yet been switched on due to the delay when a switch off com mand comes then the load will remain off Note The s...

Страница 9: ...r remain on perman ently but only for the length of the run on time The run on time is restarted if actuation is repeated This parameter is directly connected to the Manual switch off of run on time p...

Страница 10: ...l LED trailing edge phase con trol Leading edge phase control Trailing edge phase control Basic setting Universal Specifies the dimming prin ciple for the selected output Universal Automatic calibrati...

Страница 11: ...value is above the set maximum brightness or below the minimum bright ness then the system will switch to the appropriate limit value Behaviour after the end of the disabling function On Off no chang...

Страница 12: ...Basic setting 2 Specifies the priority for recall ing and removing a scene of type Restraint for the channel Activate forced operation brightness value 0 100 Basic setting 100 Defines the behaviour o...

Страница 13: ...n is 0 Switch off brightness over shoot On Off Basic setting On Allows automatic switch off according to the brightness If the parameter is On then the light controller switches off automatically when...

Страница 14: ...Check manufacturer s instructions Exchange lamps for another type Cause 2 Dimming principle and lamps do not optimally match Check operation in another dimming principle reduce connected load as well...

Страница 15: ...current Cause 5 load failure Check load replace lamp For inductive transformers check primary fuse and replace if necessary Lamps flicker or buzz proper dimming not possible device buzzes Cause 1 Inco...

Страница 16: ...dimming actuator 1 gang mini ALBRECHT JUNG GMBH CO KG Volmestra e 1 58579 Schalksm hle GERMANY Telefon 49 2355 806 0 Telefax 49 2355 806 204 kundencenter jung de www jung de 16 16 82580733 14 10 2019...

Отзывы: