eNet radio transmitter modules
and then the actuator status/group status
–
LED turns green for 3 seconds:
At least one actuator is switched on, or one Venetian blind is not in the top end position
–
LED remains off:
All the actuators are switched off or the blinds are all in the upper end position
or - if there is no status message from an actuator - a transmission error.
–
The LED rapidly flashes red for 5 seconds:
The status message of at least one actuator is missing
Channel assignment of the wall transmitter
Figure 2: Channel assignment of wall transmitter module 1-gang, 2-gang, 3-gang and 4-gang
Operating light
■
Switching: Press button for less than 0.4 seconds.
■
Dimming: Press the button for longer than 0.4 seconds. The dimming process ends when
the button is released.
■
Switching on dimmer actuators at minimum brightness: Press the bottom button for longer
than 0.4 seconds.
■
Switching on dimmer actuators at minimum brightness and dimming to maximum bright-
ness: Press the top button for longer than 0.4 seconds.
Operating blind
■
Moving the Venetian blind: Press the button for longer than 1 second.
■
Stopping or adjusting the Venetian blind: Press the button for less than 1 second.
Operating push-button actuator
■
Press the button. The load is switched on for the duration of the button-press.
The maximum actuation length is 60 seconds.
Recalling scenes
■
Press the scene button briefly.
Actuators switching to the saved scene.
Changing scene
■
Press the scene button briefly.
3 / 9
32579243
21.06.2019
J082579243