LB management
Motion and presence detector
Operation using 2-wire or 3-wire extension with button cover or push-button
Multiple extensions can be combined with each other. All operations described here are also
possible via the app. Operation with the rotary dimmer extension is described in the rotary dim-
mer extension instructions.
Switching on light for the duration of the run-on time
Short-time operation: When pressed, pulses are generated approx. every 3 seconds for 1
minute. Exception for 3-wire extension: only one pulse is generated.
■
Press the button cover or push-button briefly.
Motion detector operation: If the button cover or push-button is pressed again after
switching on, the run-on time is restarted. In combination with a dimming insert, switch-on
brightness is switched on again.
Switching the light off for 3 minutes
This function can only be used in presence detector operation.
■
Press the button cover at the bottom or push-button briefly.
The light is switched off for the period of 3 minutes. When movements are detected, the
time is restarted.
Adjust the brightness, only in combination with dimming insert
■
Long press on button cover at the top or bottom or push-button.
Save switch-on brightness, only in combination with dimming insert
■
Adjust the brightness.
■
Press the button cover over entire surface for longer than 4 seconds.
An push-button cannot be used to save the switch-on brightness.
Delete switch-on brightness, only in combination with dimming insert
■
Press the button cover briefly: Light switches on at the saved switch-on brightness.
■
Press the button cover over the entire surface for longer than 4 seconds: Switch-on
brightness is deleted. Switching on takes place at the last brightness value set.
A push-button cannot be used to delete the switch-on brightness.
6
Information for electrically skilled persons
DANGER!
Mortal danger of electric shock.
Disconnect the device. Cover up live parts.
Detection field and range
The device has a detection field of 360°. The diameter of the detection field depends on the in-
stallation height and the direction of motion of persons in the detection field. The detection field
becomes larger the greater the installation height, while the detection density and sensitivity are
reduced at the same time.
4 / 13
82599323
25.10.2019
J0082599323