When operating an extension with motion detector covers, it should be noted that the
lighting can only be switched on after a lockout time of approx. 3 seconds.
6.2 Commissioning
Testing the detection area with automatic switch standard
The insert is installed and the cover is attached.
o
Perform test settings (picture 2); remove cover plate (4) to do this.
Move brightness adjuster (6) to
3
symbol;
Set
Sens.
adjuster to max.
o
Switch on mains voltage.
The motion detector carries out a self test for approx. 60 seconds.
o
Leave the detection area and observe the switching behaviour.
If the motion detector switches on, then sources of interference must be hidden (see
Limiting the detection area) or the sensitivity reduced.
o
Measure the detection area.
Detection area is too large, limit the detection area (see Limiting the detection area).
Detection area is too small, expand the detection area using an extension.
o
Make the operating settings for the sensitivity and brightness threshold.
o
Snap cover on.
Testing the detection area with automatic switch universal
The insert is installed and the cover is attached.
o
Remove slide switch (4)
o
Perform test settings (picture 6); remove cover plate (4) to do this.
Adjuster, run-on time (8): 10 s;
Move brightness adjuster (6) to
3
symbol;
Set
Sens.
adjuster to max.
o
Switch on mains voltage.
The motion detector carries out a self test for approx. 90 seconds.
o
Leave the detection area and observe the switching behaviour.
If the motion detector switches on, then sources of interference must be hidden (see
Limiting the detection area) or the sensitivity reduced.
o
Measure the detection area.
Detection area is too large, limit the detection area (see Limiting the detection area).
Detection area is too small, expand the detection area using an extension.
o
Make the operating settings for the run-on time, sensitivity and brightness threshold.
o
Snap on slide switch.
12/14
32540233
J:0082540233
26.07.2010
Light Management
Automatic switch 180° 1.10 m