(15) Sealing flange for IP44 installation (accessories)
i
IP44 installation is only possible with IP44 automatic switches.
o
Insert the supplied red setscrews (14) for the anti-theft protection into the boreholes of the
insert (1) provided for that purpose (picture 10).
o
In the case of IP44 installation insert the sealing flange (15) into an appliance box
according to DIN 49073 and install the flush-mounted insert.
o
Position the frame (2) and attach the motion detector cover (3).
o
Fasten motion detector cover with the insert (1) using the enclosed screws (13). Do not
tighten the screws too far, because otherwise the setscrews (14) will be damaged.
o
If necessary, insert cover plate element (12) into the design cover (11) (see Limiting the
detection area).
o
Press design cover (11) onto the motion detector cover (3).
o
Snap on slide switch (4).
Installation for AS, A ranges and SL500:
picture 11: Installation AS, A ranges and SL 500
o
In the case of IP44 installation insert the sealing flange (15) (accessories) into an
appliance box according to DIN 49073 and install the flush-mounted insert (1) (picture 11).
i
IP44 installation is only possible with IP44 automatic switches.
o
Position the frame (2) and attach the motion detector cover (3). For IP44 installation, attach
the motion detector cover together with the seal (16).
o
If necessary, insert cover plate element (12) into the motion detector cover (3) (see Limiting
the detection area).
o
Snap on slide switch (4).
Removing the motion detector cover from the insert
CD and LS ranges:
10/14
32540233