The JIDA (JUMPtec Intelligent Device Architecture) Standard
super
MOPS
pro
Copyright
JUMP
tec
Industrielle Computertechnik AG
Page: 42 of 93
Get Hardware Revision
Int 15h
Input:
AX
= EA04h
DX = 4648h
CL
= Board number
Output:
CL=0: Board present
CL
≠
0: Board not present
DX=6B6Fh: Function successful
DX
≠
6B6Fh: Fn.not implemented
BH=Major revision number
BL=Minor revision number
Get Firmware Revision
Int 15h
Input:
AX
= EA05h
DX = 4648h
CL
= Board number
Output:
CL=0: Board present
CL
≠
0: Board not present
DX=6B6Fh: Function successful
DX
≠
6B6Fh: Fn.not implemented
BH=Major revision number
BL=Minor revision number
Get Last Repair Date
Int 15h
Input:
AX
= EA06h
DX = 4648h
CL
= Board number
Output:
CL=0: Board present
CL
≠
0: Board not present
DX=6B6Fh: Function successful
DX
≠
6B6Fh: Fn.not implemented
BX = Last repair date.
Description:
If CL=0 and DX=6B6Fh, then BX=Last repair date. For date format see
function ” Get Manufacturing Date” .
If board was never repaired, result will be equal to manufacturing date.
Read Running Time Meter
Int 15h
(not implemented with MULTI-4)
Input:
AX
= EA07h
DX = 4648h
CL
= Board number
Output:
CL=0: Board present
CL
≠
0: Board not present
DX=6B6Fh: Function successful
DX
≠
6B6Fh: Fn.not implemented
BX=Running time (hours)
CH=Overflow counter
ReadBoot Counter
Int 15h
(not implemented with MULTI-4)
Input:
AX
= EA08h
DX = 4648h
CL
= Board number
Output:
CL=0: Board present
CL
≠
0: Board not present
DX=6B6Fh: Function successful
DX
≠
6B6Fh: Fn.not implemented
BX = Boot counter
Get Contrast setting
Int 15h
Input:
AX
= EA20h
DX = 4648h
CL
= Board number
Output:
CL=0: Board present
CL
≠
0: Board not present
DX=6B6Fh: Function successful
DX
≠
6B6Fh: Fn.not implemented
CH = Actual contrast value (range 0..63)
not supported on
super
MOPS
pro