6 Conf
ig
ur
at
io
n
31
Ramp stop
Activating the ramp stop via a logic input holds the ramp function. The setpoint display flashes.
After the ramp stop has been de-activated, the ramp function continues with the ramp setpoint
at the time of the ramp stop.
Re-starting the ramp
h
Re-start the ramp with
D
+
I
or via the logic input
Parameter Value range
factory-set Notes
rASd 0—999 digit/h
or digit/min
1
0
ramp gradient
1. In the display with one or two decimal places, the value range changes to 0.0 — 99.9 digit/h (digit/min.)
C113 Ramp function
X
X X
Ramp function off
0
Ramp function (time base: minutes)
5
Ramp function (time base: hours)
6
k
= factory setting
X = position functionally not relevant