6 T
echnical data
18
Output
Supply
Housing
Electrical data
Relais K1 (changeover contact)
150,000 operations at 10A/250V AC 50Hz resistive load
800,000 operations at 3A/250V AC 50Hz resistive load
Supply voltage
230V AC +10/-15%, 48 — 63Hz or 115V AC +10/-15%, 48 — 63Hz
(isolated from measurement input)
12 — 24V DC +15/-15%, 24V AC +15/-15%, 48 — 63Hz
(not isolated from measurement input)
Power consumption
< 2VA
Material
polycarbonate
Mounting
DIN rail 35mm x 7.5mm to EN 50 022
Operating position
unrestricted
Weight
approx. 110g
Protection
IP20
Flammability class
UL 94 V0
Data backup
EEPROM
Connection
screw terminals for wire cross-sections up to 2.5 mm
2
Electromagnetic compatibility
interference emission
immunity to interference
EN 61 326
Class B
to industrial requirements
Electrical safety
EN 61 010, Part 1, overvoltage category III, pollution degree 2
Содержание B 70.1050.0