9
4 Installation
4.2
Temperature probes in immersion sleeves (902438/30, 902438/32)
AL
max. according to DIN EN 1434
AL
max. according to DIN EN 1434
Connecting cable
Conductor end
Ferrule
Connecting cable
Conductor end
Ferrule
Example plate
Example plate
Strain relief
Protection tube
Temperature sensor
DIN EN 60751
Protection tube
Temperature sensor
DIN EN 60751
Fastening
screw
for mounting
in thermowells
(immersion
sleeves),
sealing hole
(optional)
PL cable, mounting in immersion sleeves
Basic type 902438/30
Type with fastening option
Basic type 902438/32
Immersion depth
min. 30 mm
30
≥
Immersion depth
min. 30 mm
30
≥
Insertion length
EL
= 105 to 450 mm
Insertion length
EL
= 105 to 400 mm
Ø 6
-0.03
-0.14
Ø 6
-0.03
-0.14
Protection tube tolerance Ø 6
-0.03
-0.14
on 50 mm length
on 50 mm length
Protection tube tolerance Ø 6
-0.03