Easytech - planting
SEEDS MONITORING
Occurrences
Possible Causes
Note
Solutions
Seed monitoring is not
operating
Power cable (CM1 PWR) 12v of the
seed module (broken or improperly
fitted)
Use of multimeter
/ check for
connectors
improperly fitted
/ connectors pins
insulated by dirty
or bent
misaligned.
Observe in the
“measurement
function” the
seeds monitoring
behavior.
Clean and check the
connector sockets and
pins / Replace Sensors /
Replace Cable
Communication cable (CM1 Can) of
module (broken or improperly fitted)
Power cable (CM2, CM3, CM4) of the
seed module (broken or improperly
fitted)
Some Seed Sensors are
not operating
Power supply 12v is not supplying
the sensor (Cable broken)
Use of multimeter
Change the Sensor
Dirty in the sensor
Clean the Conductor
Machine configuration
Machine has 10
lines, however
identifies 7
Configure
OCCURRENCES
PNEUMATIC SPRINGS
Occurrences
Possible Causes
Note
Solutions
Pneumatic springs are
not inflating / valves do
not stop turning on and
off
Check if the Motor switch is ON
Visual identification
Power on the switch
Check if the register is not closed
Open the Registers (6 bar)
Check the Hoses and Springs for
leakage
Troubleshoot leakages
Check if the pressurizing and
depressurizing valves position are
totally horizontal
Change position
The do compressor
motor does not run
Cable Connector (CP2) improperly
fitted / connectors pins insulated by
dirty or bent, misaligned
Use of multimeter in
terminals
Change the cable
Check if 12v of voltage is supplying the
motor
Battery / Alternator