Jumil 3060PD Скачать руководство пользователя страница 10

10

Easytech - planting

3.2 - Seed Configuration

To configure the seed rate to be applied, click on the 

 function in the work main screen.

Checking the seeds volume:

BECKER

CURSOR

SELECT

MENU

CURSOR

BACK

In the field 

Seeds in 50ml

 enter the number of seeds collected in the Becker that comes with the machine. 

This value is important for the seeds deposit volumetric reference.

ATTENTION:

For the seeds deposit volumetric reference ideal operation, make sure that the collected value is related 

to the volume requested in the display. It is recommended that the value entered is the average of 3 samples 

and that the procedure is redone whenever there are any changes in the type or seed sieve used.

In the field 

Rate

, enter the number of seeds per meter to be distributed per row;

In 

Seed disc

, select the quantity of holes of the disc that is being used;

In 

Target speed

, enter the desired speed to perform the work. (NOTE: This value serves only as reference for 

the statistics of excessive speed during the planting);

Also observe that in the 

 function we have available the following complimentary information to the 

operator.

Population

: Population of plants per hectare;

Maximum Capacity

: Operational yield according to the target speed established expressed in hectares per 

worked hour;

Spacing

: Distance between planting rows that is being used in the seeder.

3.3 - Manure Configuration and Calibration

To configure the manure rate to be applied, click on the 

 function in the work main screen.

SYSTEM OPERATION

Содержание 3060PD

Страница 1: ......

Страница 2: ......

Страница 3: ...ts in technology have made the company to develop a great capacity of adaptation due to the demands required by the national and international markets JUMIL is genuinely Brazilian independent and has...

Страница 4: ......

Страница 5: ...3 3 Manure Configuration and Calibration 10 3 4 Brachiaria Gauging 13 3 5 Pneumatic Springs Configuration 14 3 6 Stop Motors Function 14 3 7 Deposits Volumetric Reference 15 3 8 Seeds Monitoring 15 3...

Страница 6: ......

Страница 7: ...lic motors and an electronic controller mi nimizing the vibrations in seeders fertilizers making the operation more accurate and efficient Its simple interface enables a quick and dynamic handling You...

Страница 8: ...THE EASYTECH Make sure that all the electronic components and cables are properly secured and away from the machine moving parts that might damage them Cables can not be cut twisted or excessively ben...

Страница 9: ...incorrect operation can cause physical damage to the system or any component Incorrect system configurations can also cause functional damages due to the equipment malfunctioning 3 1 Easytech System...

Страница 10: ...any changes in the type or seed sieve used In the field Rate enter the number of seeds per meter to be distributed per row In Seed disc select the quantity of holes of the disc that is being used In...

Страница 11: ...s plastic bags and buckets in the manure distributors and then press to start the procedure The manure deposit volume occurs automatically after its calibration ATTENTION Make sure that the hydraulic...

Страница 12: ...all the material and weight it with the assistance of a precision scale Enter the value of the sum generated of all the collected lines in the field Total Collected and inform the quan tity of lines c...

Страница 13: ...a dosers opening are adjusted cor rectly according to the desired rate and configured in the display To start the checking procedures for the rate applied to each brachiaria click on the function adju...

Страница 14: ...ed during the brachiaria box gauging procedure Repeat the process until the practical value collected matches with the theoretical value informed 3 5 Pneumatic Springs Configuration To adjust the pneu...

Страница 15: ...markers level To confirm click on For further information read the item 3 2 Seed Configuration SYMBOL FOR STOP MOTOR STOP MOTOR ACTUATION BUTTON ATTENTION For the perfect operation of these reference...

Страница 16: ...n is available only for the combined machines configuration where without leaving the tractor the operator can power off the machine A or the machine B manually in the display to perform the finishing...

Страница 17: ...is screen the following information is available to the operator All of worked area Worked hours Excess of speed in relation to the established for the planting 3 11 Machine Under Transportation Warni...

Страница 18: ...e and change the working mode state to tests mode the tractor hydraulic system must be powered on in working rotation ATTENTION When selecting the motor you intend to operate make sure that there is n...

Страница 19: ...e Gauging return to the work screen and select the button MENU MEASUREMENTS SE EDS MONITOR When the checking is concluded return to the menu test mode seeds monitor and selection the option working mo...

Страница 20: ...s displaying failures non compliant with the reality High population error Increases the error tolerance for the seed monitoring rate Lifting sensor Deactivates the lifting sensor inf it is damaged du...

Страница 21: ...surement function Change the Encoder Tighten the Support Encoder Cable broken C4 Encoder Replace the Cable Connectors improperly fitted connectors pins insulated by dirty or bent misaligned Clean and...

Страница 22: ...sor Cable broken Use of multimeter Change the Sensor Dirty in the sensor Clean the Conductor Machine configuration Machine has 10 lines however identifies 7 Configure OCCURRENCES PNEUMATIC SPRINGS Occ...