HL, SL
15
HL
SL
Temperature selection
digital
via keypad
indication on LCD DIALOG-DISPLAY (°C/°F)
remote control via PC
indication on monitor
Temperature indication
VFD COMFORT-DISPLAY (°C/°F)
Resolution
°C
0.01
ATC3
INT / EXT
°C
±3 / ±9
Temperature control
ICC - Intelligent Cascade Control
Heater wattage (at 230 V)
Heater wattage (at 115 V)
kW
2.0
3.0
Temperature selection
kW
1.0
-----
Electronically adj. pump capacity
stages
1 ... 4
1 ... 4
Flow rate
at 0 bar
l/min
22 ... 26
22 ... 26
Max. pressure
at 0 liters
bar
0.7
0.7
Max. suction
at 0 liters
bar
0.4
0.4
Electrical connections:
See page 16
Ambient temperature
°C
5 ... 40
5 ... 40
Mains power connection
V/ Hz
208-230 / 50/60
208-230 / 50/60
Current draw
(at 208 V / 230 V)
A
8 / 9
12 / 13
Mains power connection
V/ Hz
100-115 / 50/60
-----
Current draw
(at 100 V / 115 V)
A
9 / 10
-----
All measurements have been carried out at: rated voltage and frequency
ambient temperature: 20 °C
Technical changes without prior notification reserved.
Information about the used refrigerants
The
Regulation (EU) No. 517/2014 on fluorinated greenhouse gases
applies to all systems which
contain fluorinated refrigerants and replaces (EC) 842/2006.
The aim of the Regulation is to protect the environment by reducing emissions of fluorinated
greenhouse gases.
Among other things it regulates the emission limits, use and recovery of these substances. It also
contains requirements for operators of systems which require / contain these substances to function.
Under Regulation 517/2014, the operator of a system of this nature has the following duties:
•
The operator must ensure that the equipment is checked at regular intervals for leaks.
•
These intervals depend on the CO
2
equivalent of the system. This is calculated from the
refrigerant fill volume and type of refrigerant. The CO
2
equivalent of your system is shown on
the model plate.
•
The operator undertakes to have maintenance, repair, service, recovery and recycling work
carried out by certified personnel who have been authorized by JULABO.
•
All such work must be documented. The operator must keep records and archive them for at
least five years. The records must be submitted to the relevant authority on request.
Refer to the text of the Regulation for further information.