65
−
Supply voltage
Single phase 200V / 220V / 240V
3-phase 200V / 220V / 240V
Frequency
50 Hz / 60 Hz
Rated currency
4.6A / 4.3A / 4.0A
3.0A / 2.7A / 2.3A
Operating
environment
10. FOR GENERAL EXPORT
Temperature : 0 to 40˚C Humidity : 90% or less
11. SETTING FOR FUNCTIONS
(1) Names and functions of the respective sections of the electrical box (SC-905).
4
Selection and setting of the various functions can be performed with four setting switches and an
indicator of the SC-905.
1
Switch for confirming the contents of change and updating setting No. in DOWN direction (SET-)
2
Switch for confirming the contents of change and updating setting No. in UP direction (SET+)
3
Down switch (DOWN)
4
Up switch (UP)
WARNING :
To avoid possible personal injuries caused by movement other than that you desired, do not operate
the switches in the procedure other than those required, as described below, to specify the functions.
(Caution) Do not perform switch operations other than those described in the following explanations.
Be sure to re-turn the power switch ON after one second or more has passed. If the power
is turned ON immediately after turning it OFF, the sewing machine may not work normally.
In this case, turn ON the power again.
(2) How to change over to the function setting mode
1) Turn OFF the power to the unit.
2) Pressing switch
4
, turn ON the power to the unit.
Setting
contents
Setting
No.
1
2
3
4