![JUKI SC-905 Скачать руководство пользователя страница 79](http://html1.mh-extra.com/html/juki/sc-905/sc-905_manual-manual_2029521079.webp)
−
78
−
Corrective measure
• Set the max. traveling amount
of 1 Step to less than 8 mm.
• Set the travelling amount of the
start from the end of custom
pattern to less than 8.0 mm.
• Set the max. traveling amount
of 1 Step to less than 8 mm.
• Set the travelling amount of the
start of next sewing from the end
of condensation custom pattern
to less than 8.0 mm.
• Check or replace the panel cord.
• Re-connect the connector.
• Turn ON / OFF power.
• Re-connect CN1 connector.
• Re-connect CN14 connector
or stepping motor connector.
• Check or replace the panel cord.
• Re-connect the connector.
• Check or replace the panel cord.
• Re-connect the connector.
• Clean the filter of cooling fan.
• Re-connect the connector.
• Check the connector pin.
• Remove the cause of blown-out
and replace the fuse.
• Re-connect the connector.
• Check the connector pin.
• Remove the cause of blown-
out and replace the fuse.
No.
PE 3
PE 3
Flashing
PE 4
PE 4
Flashing
PE 5
PE 6
BTSW
LED
Flashing
1 time
BTSW
LED
Flashing
2 times
BTSW
LED
Flashing
3 times
Description and place to be checked
• Custom pattern pitch error
The max. traveling amount of 1 Step exceeds 8.0 mm at the position
specifying data of the custom pattern.
• In case the travelling amount of the start from the end of custom
pattern exceeds 8.0 mm.
• Condensation custom pattern pitch error
The max. traveling amount of 1 Step exceeds 8 mm at the position
specifying data of the condensation custome pattern.
• In case the travelling amount of the start of next sewing from the end
of condensation custom pattern exceeds 8.0 mm.
• Panel communication error
1
Disconnection of the panel cord
2
Slackness of the panel cord connector
3
Needle rocking control error
• Communication between panels error
1
Disconnection of the panel cord
2
Slackness of the panel cord connector
• Communication between panels error
1
Disconnection of the panel cord
2
Slackness of the panel cord connector
• Overheat error
An error that occurs when the temperature of the radiator on CTL circuit
board inside the control box has risen more than the specified
temperature.
• Needle rocking drive origin error
An error that occurs when the detection of the needle rocking origin is
performed and the origin is not detected at the time of turning ON the
power.
1
Disconnection of PM relay cable
2
Trouble of the origin sensor
3
Disconnection of the power transformer connector pin
4
F1 fuse has blown.
8.5 mm
Max. zigzag
width limitation