![JUKI PLC-2760NVM Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/juki/plc-2760nvm/plc-2760nvm_instruction-manual_2029497021.webp)
– 19 –
3) Press the standby switch.
4) Remove the top cover.
5) Loosen top feed cam setscrews
❻
(two pieces).
6) On the condition that the amount of the alternating
vertical movement of the walking foot and presser
foot is uniform, turn top feed cam
❺
in such a way
that needle
❶
, throat plate
❷
, walking foot
❸
and
feed dog
❹
are positioned as shown in the figure
on the left.
7) Tighten top feed cam setscrews
❻
(two pieces).
8) Attach the top cover in place.
❹
❶
❷
❸
❷
❶
❸
❹
❻
❺
❻
❺
[Conditions]
・
Amount of feed: 6 mm
・
Alternating vertical movement amount: 3 mm
・
When the needle and the walking foot come down
Top end of the eyelet of needle
❶
, top surface of
throat plate
❷
, undersurface of walking foot
❸
and
top surface of feed dog
❹
are aligned.