– 72 –
6
4
5
■
Communication setting screen
Example) Sewing pattern No. 8 is uploaded as the parameter form file No. 15 of the smart media.
1
. Open the smart media cover and insert the smart media (Optional Part No. : HX005750000) from the
insertion opening.
* Panel function does not work with the cover opened.
2
. Selection of data
EPD is selected from the beginning since the data of EPD form only is handled for LH4168,4188.
3
. Selection of communication method
Press
2
in the communication setting screen to display the communication method setting screen.
[Explanation of the pictograph]
1
Download from the smart media
2
Download from SU-1
3
Upload to the smart media
4
Upload to SU-1
Press
3
to select the upload to the smart media. Then press
5
to determine.
6
. Start of download
When all setting procedures have been completed, press
6
in the communication setting screen to start
downloading.
5
. Custom pattern No. setting
Press
4
and
5
in the communication setting screen to set the custom pattern No.
■
During communication screen
When the screen returns to the communication setting screen after display of the during communication
screen, communication is completed.