– 89 –
Error
code
Description of error
Display message
How to recover
Place of
recovery
E024
Pattern data size over
Memory size is over.
Possible to re-
start after reset.
Data input
screen
E030
Needle bar position missing
error
Needle bar is not in the
predetermined position.
Turn hand
pulley to bring
needle bar to its
predetermined
position.
Data input
screen
E031
Air pressure drop
Air pressure is dropped.
Re-start is
enabled after
resetting the
machine following
the restoration of
the air pressure.
Previous
screen
E032
File interchanging error
File cannot be read.
Possible to re-
start after reset.
Data input
screen
E040
Sewing area over
Possible to re-
start after reset.
Sewing
screen
E043
Enlarging error
Sewing pitch exceeds Max. pitch.
Possible to re-
start after reset.
Data input
screen
E045
Pattern data error
Possible to re-
start after reset.
Data input
screen
E050
Stop switch
When stop switch is pressed
during machine running.
Possible to re-
start after reset.
Step
screen
E052
Thread breakage detection
error
When thread breakage is
detected.
Possible to re-
start after reset.
Step
screen
E061
Memory switch data error
Memory switch data is broken or
revision is old.
Turn OFF the
power
E080
External stop switch
Possible to re-
start after reset.
Step
screen
Содержание AMS-221F