– 69 –
No.
Name
Selection item
Setting
range
Unit &
Meaning
Initial value
SS 2516 HS 2516 SL 2615 HL 2516 HS 3020
SL
2516 FU
HL
2516 FU
U024
Thread tension for the 3th stitch at the
beginning of sewing
(With the thread clamp)
0 to 200
1
0
U026 2-step stroke position of the mo-
tor-controlled feeding frame
50 to 90
1
70
U030 Setting of the thread tension output
0: Standard (linear)
1: Low-tension detailed setting
2: Hight-tension detailed setting
0 to 2
-
0
U032 Buzzer selection
0: Without buzzer sound
1: Panel operating sound
2: Panel operating sound + error
0 to 2
-
2
U033 Number of stitches to be sewn before
the thread clamp releases the thread
1 to 7
1 stitch
2
U034
Setting the thread clamp driving timing
(reference: 80 °)
Set with 4 ° (TG resolution)
+ : Advanced
- : Retarded
-40 to 0(°)
1 (°)
0
U035 Thread handling at the beginning of
sewing
0: Thread clamping
1: Thread trimming
2: No handling
0 to 2
-
1
U037 Selection of lifting of the feeding frame
at the end of sewing
0: Feeding frame goes up after re-
turning to the sewing start position
1: Feeding frame goes up and returns
to the sewing start position
2: Feeding frame goes up when the
feeding frame switch is pressed
after returning to the sewing start
position
3: Feeding frame goes up when the
feeding frame switch is pressed
after moving to the sewing start
position / sewing machine starts
sewing with the start switch
0 to 3
-
0