– 68 –
No.
Name
Selection item
Setting
range
Unit &
Meaning
Initial value
SS 2516 HS 2516 SL 2615 HL 2516 HS 3020
SL
2516 FU
HL
2516 FU
U012 Sewing speed for the 3th stitch of soft
start (Without the thread clamp)
200 to
2,800
100
sti/min
1,000
U013 Sewing speed for the 4th stitch of soft
start (Without the thread clamp)
200 to
2,800
100
sti/min
1,500
U014 Sewing speed for the 5th stitch of soft
start (Without the thread clamp)
200 to
2,800
100
sti/min
2,000
U016
Thread tension changeover timing at
the beginning of sewing (in the case
of without thread clamping) (reference:
60 °)
Set with 4 ° (TG resolution)
+ : Advanced
- : Retarded
-20 to 8(°)
1 (°)
0
U019
Thread tension for the 1st stitch at the
beginning of sewing
(With the thread clamp/ With the bird's
nest reducing operation)
0 to 200
1
200
U020
Thread tension for the 2nd stitch at
the beginning of sewing
(With the thread clamp/ With the bird's
nest reducing operation)
0 to 200
1
200
U021
Thread tension for the 3th stitch at the
beginning of sewing
(With the thread clamp/ With the bird's
nest reducing operation)
0 to 200
1
200
U022
Thread tension for the 1st stitch at the
beginning of sewing
(With the thread clamp)
0 to 200
1
0
U023
Thread tension for the 2nd stitch at
the beginning of sewing
(With the thread clamp)
0 to 200
1
0
Содержание AMS-221F