– 109 –
Error code
Display
Description of error
Display message
How to recover
Place of
recovery
E802
Power electrical
discontinuity detection
Turn OFF
the power
E811
Overvoltage
When input power is more
than the specified value.
Turn OFF
the power
E813
Low voltage
When input power is less
than the specified value.
Turn OFF
the power
E901
Main shaft motor IPM
abnormality
When IPM of servo control
p.c.b. is abnormal.
Turn OFF
the power
E903
Stepping motor power
abnormality
When stepping motor power
of SERVO CONTROL p. c. b.
fluctuates more than ± 15%.
Turn OFF
the power
E904
Solenoid power
abnormality
When solenoid power of
SERVO CONTROL p. c. b.
fluctuates more than ± 15%.
Turn OFF
the power
E905
Heat sink temperature for
SERVO CONTROL p. c. b.
abnormality
Turn ON the power again
after taking overheat time of
SERVO CONTROL p. c. b.
Turn OFF
the power
E907
X feed motor origin
retrieval error
When origin sensor signal
is not inputted at the time of
origin retrieval motion.
Turn OFF
the power
E908
Y feed motor origin
retrieval error
When origin sensor signal
is not inputted at the time of
origin retrieval motion.
Turn OFF
the power
E910
Presser motor origin
retrieval error
When origin sensor signal
is not inputted at the time of
origin retrieval motion.
Turn OFF
the power
E913
Thread clamp origin
retrieval error
When origin sensor signal
is not inputted at the time of
origin retrieval motion.
Turn OFF
the power