![JUKI AMS-221ENTS Скачать руководство пользователя страница 105](http://html.mh-extra.com/html/juki/ams-221ents/ams-221ents_instruction-manuals_2029624105.webp)
– 101 –
No.
Item
Setting range
Edit unit
Pedal SW1 with/without latch
---
---
Without
With
Pedal SW2 with/without latch
---
---
Without
With
Pedal SW3 with/without latch
---
---
Without
With
Pedal SW4 with/without latch
---
---
Without
With
Enlarging/reducing function mode
---
---
Prohibited
Jog move function mode
---
---
Prohibited
Parallel move
Retainer compensation motion : selection of motion
---
---
Without motion
With motion
Selection of needle upper dead point at the time of origin
retrieval/return to origin
---
---
Without
With
Temporary stop : thread trimming operation
---
---
Automatic thread trimming
Manual (Thread trimming by
turning Stop SW ON again)
Main motor X/Y feed synchronized control : speed/pitch
---
---
2500 sti/min/
3.5mm
2200 sti/min/
3.5mm
1800 sti/min/
3.5mm
1400 sti/min/
3.5mm
Increasing/decreasing
pitch (Number of stitches
is fixed.)
Increasing/decreasing
number of stitches (Pitch
is fixed.)
2nd origin specified later