![JUKI AMS-221ENTS Скачать руководство пользователя страница 111](http://html.mh-extra.com/html/juki/ams-221ents/ams-221ents_instruction-manuals_2029624111.webp)
– 107 –
Error code
Display
Description of error
Display message
How to recover
Place of
recovery
E061
Memory switch data error
Memory switch data is
broken or revision is old.
Turn OFF
the power
E080
External stop switch
Possible
to re-start
after reset.
Step
screen
E204
USB connection error
With the number of times
of sewing has reached 10
or more, with a USB device
connected to the sewing
machine
Possible
to re-start
after reset.
Sewing
screen
E220
Grease-up warning
At the time of operation of
100 million stitches
→
Refer to
Replenishing the
designated places with
Possible
to re-start
after reset.
Data
input
screen
E221
Grease-up error
At the time of operation of
120 million stitches
The sewing machine is put
in the sewing-impossible
status. It is possible to
clear with memoryswitch
.
→
Refer to
Replenishing the
designated places with
Possible
to re-start
after reset.
Data
input
screen
E302
Head tilt confirmation
When head tilt sensor is
OFF.
Possible
to re-start
after reset.
Previous
screen
E305
Cloth cutting knife
position error
Cloth cutting knife is in the
regular position.
Turn OFF
the power
Data
input
screen
E306
Thread clamp position
error
Thread clamp unit is not in
the regular position.
Turn OFF
the power
E307
External input command
time out error
Input is not performed for a
fixed period of time with the
external input command of
vector data.
Possible
to re-start
after reset.
Data
input
screen