background image

4

JPK 3

Concerning these Operation Instructions

field-specific and security-accordant  ac-
cepted rules for  professional  working have
to be also taken into consideration.

These operation instructions have therefore
to be read obligatorily by the assemblyman,
as well as by the responsible  trained per-
sonal /  the operating person before the in-
stallation, the putting into operation and the
servicing.

Not only the general security advices in-
cluded in the chapter “Intended Use”
have to be observed, but also the specif-
ic security advices integrated under the
other gists.

1.1

Used Symbols

The security advices contained in theses op-
eration instructions are marked by the fol-
lowing symbols: 

 

Indications directly affixed to the sample wa-
ter cooler, as for example:

Flow direction (see fig.1)

Type plate

Cleaning tips

have to be paid attention to imperatively,
and have to be kept in  a completely legible
state.

1.2

Security Advices and Dan-
gers in Case of  Non-compli-
ance

In detail the non-compliance of the general
danger symbols can bring about the follow-
ing endangerments:

Failure of important functions  of the
sample water cooler.

Imperilment of persons caused by elec-
trical and mechanic influence.

Imperilment of  persons and  environ-
ment, caused through leakage.

Each kind of a security dangerous mode of
operation has to be avoided.

The non-observance of these operating in-
structions  and their safety advices can im-
plicate a peril concerning the environment
and the sample water cooler.

1.3

Used  Units

At variance with International System of
Units [SI= System International, the follow-
ing units have been applied:

ATTENTION

Indication to 
existent dan-
gers

Warning, electrical voltage.

Application tips and other infor-
mation’s.

Fig. 1:

Built-in rotary flange

Unit

Conversion

°F

°F = 9/5°C + 32

bar

1 bar = 10

5

 Pa = 0,1 N/mm²

¾" DN 

20

°e

°e = 0.142 mmol/l alkaline
earth ions

Содержание JPK 3

Страница 1: ...ing and putting the unit into service These must always be issued to the owner user Prolongated guarantee period if a maintenance contract has been concluded Installation and Operating Instructions JU...

Страница 2: ...rints even of extracts is only permitted with special approval Dear Customer We would like to thank you for your con fidence in us which you have shown by purchasing this device The product you have p...

Страница 3: ...ooler These operation instructions shall make it easier to become acquainted with the sam ple water cooler and to profit from its intend ed field of application The operation instructions contain impo...

Страница 4: ...attention to imperatively and have to be kept in a completely legible state 1 2 Security Advices and Dan gers in Case of Non compli ance In detail the non compliance of the general danger symbols can...

Страница 5: ...e obser vance of the operation instructions Before using the sample water cooler bey ond the utilization limits stated in the opera tion manual the manufacturer supplier ha ve by all means to be conta...

Страница 6: ...water cooler the free space should not be less than 250mm These distances are necessary in order to be in a position to effectuate and easy operation and maintenance in a proper way For the shut off...

Страница 7: ...lt in rotary flange can be caused Considerable water damages can be the consequential effect Persons that stay near to the sample water cooler are exposed in that case to a sani tary risk due to hot w...

Страница 8: ...l of hot water samples is not only dangerous but leads inevitably to imprecise and false analysis results Therefore the measurement of the content of oxygen binder is not possible due to the fact that...

Страница 9: ...o 30 l h 0 05 up to 0 13 gpm US 0 04 up to 0 12 gpm UK Flush the Erlenmeyer flask re peatedly in order to effectuate the sam pling removal ATTENTION see chapter Security Advices and Dan gers in Case o...

Страница 10: ...tions stated in the chapters In stallation and Maintenance have to be strictly observed 5 5 Service Interruption ATTENTION see chapter Security Advices and Dan gers in Case of Non compliance In the ca...

Страница 11: ...ich can lead to brittleness right up to brittle fractures These kinds of cleaners must therefore not be used 7 2 Indicating plate ATTENTION see chapter Security Advices and Dan gers in Case of Non com...

Страница 12: ...ended to aim at the main tenance works and the supply of the con sumer and wear parts being effected by the skilled handicraft or the manufacturer client service In the sense of our General Sales and...

Страница 13: ...recipient is made of plastic equipped with connections for the cool ing water inlet BSP R and outlet as well as for the sample water inlet BSP R sample water outlet heat ex changer made of stainless...

Страница 14: ...ete state Tranport damages have to be reported within twenty four hours due to the fact that unless for actuarial reasons any adjustment of claims can be effected Measuring instrument Order number Sul...

Страница 15: ...et tester 8690001 Buffer solution 8721098 Measuring instrument Order number Item Designation Piece Order No VE1 Piece 1 Retention Sieve 1 2460023 4 2 Clamp ring screw connection 1 1450255 7 3 Erlenmey...

Страница 16: ...eu JUDO France S r L 76 Rue de la Plaine des Bouchers Technosud F 67100 Strasbourg Tel 33 0 3 88 65 93 94 Fax 33 0 3 88 65 98 49 e mail info judo fr www judo fr Installed by JUDO HEIFI SOFT Mobile so...

Отзывы: