12
JUDO i-soft TGA 2
Installation
– Then shut-off the water again (at the
stopcock or shut-off valve) and remove
the mounting cover of the rotary flange
fitting.
The connection flange of the water softening
system is covered by a white protective cap.
This protective cap is secured using four
hexagon socket head screws M6×130.
ATTENTION
After removing the white protective cap do
not reach into the device connection flange
(risk of crushing)!
– Loosen all four hexagon socket head
screws M6×130, but do not screw out
completely (bayonet connection)!
– Remove the white protective cap.
The profile of the profile flange seal must
point towards the rotary flange fitting (see
fig. 6). If this is not observed, water leaks
may occur This can result in water damage
to the building, furnishings and equipment.
– Raise the water softening system and
swivel approximately 30° in an anti-
clockwise direction.
– Place on the rotary flange fitting so that
the screw heads project through the bay-
onet holes (see fig. 7 I).
– Swivel the water softening system back
approximately 30° in a clockwise direc-
tion.
– Fully tighten the four M6×130 hexagon
socket head screws (see fig. 7 II).
After installation of the water softening sys-
tem, screw out the wall support until it touch-
es the cladding of the water softening sys-
tem and the device hangs vertically on the
wall.
4.5
Installation of the bypass
valve (accessory)
If a bypass valve is used between the rotary
flange fitting and the water softening system
it will remain possible to continue to draw a
supply of untreated drinking water during
possible maintenance on the system.
– First flush the pipe with the newly in-
stalled rotary flange fitting JQE. The ro-
tary flange fitting is still sealed by the
black mounting cover.
– Then shut-off the water again (at the
stopcock or shut-off valve) and remove
the mounting cover of the rotary flange
fitting.
– Connect the bypass valve with the rotary
flange fitting, by engaging the bayonet,
on the flange side with the cast-in letter
“R” (R=Rohr [pipe]) (see fig. 8).
Fig. 6:
Rotary flange fitting
Profile flange seal
Select the tightening torque (about
4 Nm) so that the seal is effective
and the water softening system is
not damaged or strained!
Fig. 7:
Rotary flange fitting with bayonet
I
II