Installation
WARNING
If the profile flange seal is
incorrectly seated, water can
escape causing water damage to
dwelling and furnishings.
3.
Remove the protective film from the
bypass valve without leaving any
residues.
4.
Raise the device vertically and turn
slightly
counter-
clockwise.
5.
Place the device on the device-side
flange (“G”) of the installed bypass
valve and guide the screw heads
through the bayonet holes of the
bypass valve.
6.
Turn the device attached to the bypass
valve slightly
in the
clockwise direction
to engage the screws in the holes of the
bypass valve.
7.
Tighten the four screws.
UNIT
Select the tightening torque
(approx. 4 Nm) so that the pro-
file flange seal seals effectively
and the device is not damaged or
strained.
Installation of the device is completed.
Repeat this procedure for each individ-
ual water softening system.
Fig. 4:
Position the device on JQX
(example shows softener 2)
Fig. 5:
Lock bayonet connection
(example shows softener 2)
1703525 • 2022/10
JUDO QUICKSOFT MEGA 6