background image

Intended use

JUDO QUICKSOFT MEGA 4

7

The water softening system must only be
used as intended in a technically fault-free
state, while maintaining safety and hazard
awareness, and in compliance with the op-
erating instructions.

Ensure that malfunctions are rectified
immediately!

So that the waste water can be safely
drained away both during operation and also
in the event of a possible system defect, the
specifications given in chapter 4.1.1 “Requi-
rements for the place of installation” mu
st be
closely observed!

NOTICE

(see chapter 1.2 “Safety instructions and

dangers due to non-observation”)
The spent regenerating salt is removed from
the water softening columns together with
waste water. Therefore it must not be used
for irrigation or similar purposes.
The designed capacity of the water soften-
ing system is such that it is capable of par-
tially softening the entire water requirement
for a single or multiple family dwelling as
well as corresponding partial water quanti-
ties for hot water, swimming pool, washing
machine and dishwasher.

2.1

Water pressure

The water pressure must be between 2 bar
and 7 bar.
The water pressure must not fall below 2 bar
as otherwise the function can be impaired! If
the water softening system is not regularly
serviced, the softening function can be im-
paired.

NOTICE

(see chapter 1.2 “Safety instructions and

dangers due to non-observation”)
Where the 

water pressure is greater than

7 bar

, a pressure reducer must be installed

upstream

 of the water softening system

(see fig. 1). If the operating pressure is great-
er than 7 bar, malfunctions can occur.

The optimum operating pressure for the wa-
ter softening system is between 3 bar and
5 bar. This is where it operates most eco-
nomically.

2.2

Indication of particular dan-
gers

2.2.1 Electrical devices/installations

Electrical devices/installations that are not
splash-proof and are located in the vicinity of
the water softening system may be dam-
aged by water that escapes during installa-
tion or in the event of incorrect use of the wa-
ter softening system. If the electrical
devices/installations are connected to the
power supply, it is also possible that a short-
circuit could occur. Should this occur there is
a risk of electric shocks to people. Therefore
electrical devices/furnishings and equip-
ment in the vicinity must be splashproof and/
or comply with the legal regulations for wet
areas.

 Fig. 1:

Pressure reducer upstream of the sys-

tem

We recommend installation of a
pressure reducer for

 water pres-

sures between 5 and 7 bar

.

No electrical cables and equipment
may be located below or in the im-
mediate vicinity of the water soften-
ing system!

1 = Pressure reducer

1

Содержание 8200367

Страница 1: ...Read before use and store Installation and operating instructions JUDO QUICKSOFT MEGA 4 Water softening unit Valid for EU countries and Switzerland Language English...

Страница 2: ...nfidence you have shown in us by purchasing this device In purchasing this water softening system you have procured a state of the art de vice This device is suitable for use in cold drinking water up...

Страница 3: ...JUDO QUICKSOFT MEGA 4 3...

Страница 4: ...5 Menu structure 18 5 6 Function description 19 5 7 Filling with salt 20 5 8 Potential free fault indication 21 5 9 Integration of the water softening system in building control systems 21 5 10 Connec...

Страница 5: ...to do so i e who are able to fulfil the instructions referred to in the installation and operating instructions as well as country specific regulations Alongside the operating instructions and the le...

Страница 6: ...softened must comply with the European Drinking Water Direc tive The manufacturer supplier must be consult ed before using water of a different quality or water with additional additives The water so...

Страница 7: ...em is not regularly serviced the softening function can be im paired NOTICE see chapter 1 2 Safety instructions and dangers due to non observation Where the water pressure is greater than 7 bar a pres...

Страница 8: ...and cleaning agents reduced 3 2 Materials used The materials used are resistant to the phys ical chemical and corrosive loads expected to be encountered in drinking water and fulfil the specification...

Страница 9: ...annot be safely and completely drained it is possible that property damage to the home and fur nishings may be caused by the water A shut off valve must be installed up stream and downstream of the wa...

Страница 10: ...ed by an arrow integral with the casting see fig 2 The flange surface of the rotary flange fitting must be upright The rotary flange fitting must be fitted so that it is free from mechan ical stress o...

Страница 11: ...is can result in water damage to the building furnishings and equipment Raise the water softening system and swivel approximately 30 in counter clockwise direction Place it on the parallel connection...

Страница 12: ...r next to it on the floor Fig 6 Connection of the water softening system with the salt reservoir 1 2 Marking arrow unlocked Marking arrow locked Lance Salt reservoir Note the marking arrow In doing so...

Страница 13: ...outside diameter must not be routed any higher than the control head The hose length must not exceed 3 m The safety overflow hose with 19 mm out side diameter must be routed with a steady downward slo...

Страница 14: ...nu individual values are in creased or decreased using keys and and then accepted using the OK key Sub menus Raw water hardness Raw water hardness setting see chapter 5 4 3 Raw water hardness set ting...

Страница 15: ...or coarse grains 7 15 mm If other regenerating salts are used then the salt reservoir must be cleaned at shorter intervals and the intake strainer replaced more frequently Remove the cover Enter the...

Страница 16: ...s treated If the raw water hardness is low a greater water volume is treated The water softening system is pre set to a raw water hardness of 25 e Another raw water hardness is set as follows Press ke...

Страница 17: ...es are much higher partially greater than 1000 mg sodium per litre If the calculated total sodium content ex ceeds the valve permitted by the drinking water legislation of 200 mg l then it can be corr...

Страница 18: ...Operation 18 JUDO QUICKSOFT MEGA 4 5 5 Menu structure Fig 12 Menu structure...

Страница 19: ...way soft water is always available for the consumer even during regeneration 5 6 3 Regeneration With a very short regeneration period of about 7 5 minutes per resin container total 15 minutes high vol...

Страница 20: ...brine concentration is too low the display in dicates After this message replenishment with a quantity of 25 kg of regenerating salt is re quired Then the OK key must be briefly pressed The warning m...

Страница 21: ...tegration of the water soften ing system in building control systems The water softening system can be integrat ed via the potential free relay into a building control system e g EIB LCN or LON For ex...

Страница 22: ...closed or the bypass valve is switched over When disassembled the water softening system must be stored in a dry and frost free location The connection flange must be protect ed against dirt and dama...

Страница 23: ...eration Maintenance Service req Message appears after the one year maintenance interval has elapsed see chapter 8 3 1 Message Mainte nance Service Attention Salt deficit Message appears after exceedin...

Страница 24: ...opriate hygiene measures Thus for example the salt packs should be cleaned before use so that no impurities can get into the salt dissolving container The re generating salt must be shaken into the sa...

Страница 25: ...ing sys tem Operating pres sure Rated pressure 2 7 bar PN 10 Pipe connection 1 Number of single softeners 2 Recommended number of dwelling units 3 6 Operating weight with full salt charge approx 180 k...

Страница 26: ...mixing water pipe downstream of the water softening system so that the water can be admixed proportionally with a JUL mineral solution The JUL mineral solutions contain sub stance components that stab...

Страница 27: ...Data sheet JUDO QUICKSOFT MEGA 4 27 Fig 14 Electronic control unit with fault message relay...

Страница 28: ...Spare parts 28 JUDO QUICKSOFT MEGA 4 10 Spare parts Fig 15 Spare parts JUDO QUICKSOFT MEGA 4 1 A 2 4 3 B 5 6 7 8 8 9 9 10 11...

Страница 29: ...essure regulator 2200582 88 Spare part set injector 2201470 78 A Spare part set hoses complete 2200012 25 B Spare part set overflow connection 2202230 38 1 Power supply unit EU 24 V DC 2210506 65 2 La...

Страница 30: ...30 JUDO QUICKSOFT MEGA 4 Notes...

Страница 31: ...JUDO QUICKSOFT MEGA 4 31 Notes...

Страница 32: ...eraufbereitung GmbH Filiaal Filiale BeNeLux Laarbeeklaan Av du Laerbeek 72 A1 B 1090 Brussel Bruxelles Tel T l 32 0 24 60 12 88 Fax 32 0 24 61 18 85 e mail info benelux judo eu judo eu JUDO France S r...

Отзывы: