The Muscle Tester Dynamometer

Care and Cleaning

Muscle Tester is an electronic device and, therefore, should not be submerged in 

liquid or placed in an autoclave . The device should be cleaned with a soft, 

non-abrasive cloth dampened with clean water .  Do not use solvents, detergents or 

harsh disinfectant on the PowerTrack’s plastic body .

Testing pads should be removed from the device for cleaning . Pads can be cleaned 

with a mild, non-abrasive detergent and a soft cloth . The metal connecting rod 

should be dried thoroughly after the pad is cleaned .

When not in use the device should be stored in the case provided . Avoid dropping 

or banging the device against hard objects . Never stand on, pound with or apply 

more the 125 lb . of pressure against the dynamometer .

Changing Testing Pads

Muscle Tester features a “quick release” system to make changing testing pads fast 

and easy .

To remove a testing pad, grasp the pad with your thumb and index finger at the 

notches in the dynamometer so your fingers can pull against the underside of the 

pad . Pull the pad straight out from the dynamometer .

To install a testing pad, insert the metal post into the dynamometer receptacle and 

press the pad all the way in . Make sure pad is securely in place against load cell 

before beginning a test .

Using the Dynamometer

Muscle Tester was designed to fit comfortably in the palm of your hand during 

manual muscle testing . It can be used to test with either hand . Its slim profile helps 

reduce the “roll-over” effect that can occur with taller dynamometers . However, 

Muscle Tester should always be used with your hand under the strap .

The testing pads should be selected according to the surface area where the 

dynamometer will be placed . When placing the dynamometer against the forehead 

for a cervical flexion test, the flat pad should be used . Likewise, when the 

dynamometer is placed against a curved bony area, such as the forearm, the 

curved pad should be used . The curved pad can also be rotated in the load cell to 

provide the greatest patient comfort during a test .

13

Содержание Commander MN084

Страница 1: ...2016 JTECH Medical MN084_D Muscle Tester...

Страница 2: ...shed by JTECH Medical 7633 S Main St Midvale UT 84047 United States of America 385 695 5000 800 985 8324 www jtechmedical com Authorized Representative for EU Atlantico Systems 34 Oldfield Kingston Ga...

Страница 3: ...est and Test Alt Modes 7 Testing Methods 8 Advanced Console Features 10 Reviewing an Exam 10 Statistics Definitions 12 Deleting an Exam 12 Reports 12 The Muscle Tester Dynamometer Care and Cleaning 13...

Страница 4: ...ANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE UNDER NO CIRCUMSTANCES SHALL JTECH BE LIABLE FOR ANY DIRECT INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES THE REMEDIES SET FORTH IN THIS WARR...

Страница 5: ...h off center force accuracy from 94 96 Call JTECH for accuracy report details Includes both round and curved test pads Commander Console Easy to read 2 diagonal LCD Operates during exams either as a w...

Страница 6: ...follow these policies will void the warranty Calibration To ensure accuracy the Muscle Tester and Commander console have been factory calibrated with weights traceable to the National Institute of Sta...

Страница 7: ...onal EasyDocs Impairment Module the system automatically calculates motor deficit impairments from muscle testing results For more information on upgrades contact your JTECH sales representative or ca...

Страница 8: ...n to turn the console off Exams stored in memory are not erased when power is turned off Holding the ON OFF button down for two seconds clears all stored exams The console shuts off automatically afte...

Страница 9: ...less you change the default Default settings do not change when the unit is turned off or when an exam is deleted Defaults can only be reset manually Setting Defaults Three buttons are used when setti...

Страница 10: ...the dynamometer Test recording begins when the default threshold force is exceeded A test ends when force on the dynamometer drops back below the threshold The display then indexes to the next repetit...

Страница 11: ...REP 1 RIGHT NOTE After completing a test Commander prevents inadvertent deletion of tests previously stored in memory by indexing to the next test not completed For example if test 2 was completed pre...

Страница 12: ...rt In this example the test number on the display corresponds to the pre printed test number on the worksheet This method eliminates the necessity of writing the test number on the worksheet before or...

Страница 13: ...tition press TEST CONT To erase the repetition and start over press REDO Deleting a test Press REVIEW then press NEXT until the correct test number is displayed While holding the REVIEW button down pr...

Страница 14: ...e Maximum Force Repetition 2 Left Side CV Left Side Bilateral Deficit Left Side REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW After all statistics have been selected the dis play circles back to the begin...

Страница 15: ...econds or until the unit reactivates When the button is pressed unit console will beep and turn off indicating data has been erased Note All test default values will be retained Reports Muscle testing...

Страница 16: ...humb and index finger at the notches in the dynamometer so your fingers can pull against the underside of the pad Pull the pad straight out from the dynamometer To install a testing pad insert the met...

Страница 17: ...ral ner vous system are ruled out Manual muscle testing should never be used alone to diagnose but should be used in conjunction with other diagnostic testing tools such as the Dualer dual inclinometr...

Страница 18: ...tester and the JTECH s IsoTrack isometric testing station the system has been modified slightly to encompass the additional diagnostic data available When Should a Muscle Test Be Graded Using the trad...

Страница 19: ...ustifying treatment or determining the injured dis eased nerves Grading without the Muscle Testing Dynamometer If the subject does not have sufficient strength to resist against the force gauge or a f...

Отзывы: