Multi Printer
22
FORM 3
Press “ENT” key to save the tare value of the measured data. Prints
Gross/TARE/NET by saving the “TARE” value in “ENT” key, and
recognizing next measured data as “NET”.
P
ress “ENT” key to save the first measured data (not printed).
After, weighing data makes print by print key "0" key while realizing
“NET”' value continuously.
: Ready to receive TARE value by pressing
“ENT” key.
: when TARE data is saved,
“TARE SAV” is displayed
for 2 seconds on the screen.
: Press
“0” key to save the net data and print.
e.g. )
[Measured Data Printing ] [ Total Printing ]
※
Average, maximum and minimum are based on GROSS value for
TOTAL printing.
MANUAL 2
PUSH PRN
MANUAL 2
TARE SAV
MANUAL 2
PUSH PRN
SERIAL : 001
CODE : 00000001
GROSS : +36.450 kg
TARE : +1.300 kg
NET : +35.150 kg
SERIAL : 002
CODE : 00000001
GROSS : +58.600 kg
TARE : +1.300 kg
NET : +57.300 kg
2005-02-16 17:23:40
계량횟수
002 90.78 g
= = = = = = = = = = = = = = = =
*****< TORAL >*****
2014-04-08 17:25:50
CODE 00000001
Weighing Count 002
GROSS +95.050 kg
TARE +2.6000 kg
NET +92.450 kg
Average +47.450 kg
Max. +58.600 kg
Min. +36.450 kg
Range 22.150 kg
Standard Devi. 1.25 kg
Variation (%) 2.629 %
= = = = = = = = = = = = = = = =