background image

©JRI  

1

2

3

2

 

 
 
 
 
 
 
 
 

 
To start the SPY RF, press between 3 and 10” on the button:  

-

 

the 2 LEDs are on and flash at the same time 

-

 

The green led blinks evry seconds 

 

To stop the Spy RF, press on between 3 to 10’’ on the button 

-

 

the 2 leds are on and and flash one after the other. 

Stop is possible only if there is no alarm, otherwise acknowledge it before with Sirius. 
 

V.

 

BATTERY CHANGE 

 

 
 
 
 
 

 

 
 
 
 
 
 
 

 

 
 
 

VI.

 

RESET 

If the device does not work anymore (cannot turn it on…), use the Reset function in the same way as the battery change. 

VII.

 

CHARACTERISTICS 

Duration alarm on 

Suitable 

Duration alarm off 

Suitable 

Operating range 

-10°C +70°C 

Storage range 

-40 + 85°C 

Radio range (in free field) 

1km 

Radio band 

868MHz or 902MHz 

Power supply 

9 VDC – 300 mA* 

battery life 

200 

alarms or 2years 

Dimensions 123x69x30mm 
Protection degree 

IP34 

EN 12 830 compliance 

Yes : this device must be regularly checked according to  

EN 13 486 (1 time per year recommended) 

CE ERM compliance 

EN 301 489 / EN 61000 / EN 61010 EN 55022 / EN 300 220 

FCC compliance 

FCC part 15 

Supplied for the european market 

KEEP THE BATERY FAR FROM THE FIRE ; DO NOT TRY TO RELOAD OR TO SHORT CIRCUIT IT. USE ONLY BATTERIES 

SUPPLIED BY JRI (REF 06569) 

!

a) 

Unplug the battery connector

.

  

b)  

Short circuit the 2 pins with a screwdriver

 

c) 

Connect the new battery

 

d) 

Change the seal

 

e) 

Close the battery cover

 

Never unscrew. 

This will cancel 

the warranty 

1

Open the 

battery cover 

AlarM 

AlarM

>3’’ / <10’’ 

Содержание SPY RF AlarM

Страница 1: ...USER MANUAL Spy RF Alarm 06255D ...

Страница 2: ...s 3 III PRESENTATION 4 IV INSTALLATION 4 a Installation recommendations 4 b Installation of wall mounting bracket 4 c Activation 4 V BATTERY CHANGE 5 VI RESET 5 VII CHARACTERISTICS 5 VIII ADDING SPY RF ALARM IN SIRIUS 6 a Setting up 7 b Sending remote alarm 7 IX WARRANTY 8 X MAINTENANCE CONTRACT 8 XI ENVIRONMENT PROTECTION 8 ...

Страница 3: ...ivered by a main power supply adaptor 230VAC Comply to the security and utilization regulations of electric power Use an electric installation complying with these regulations CE MARKING this equipment is certified to comply with the European regulation for the electric security inflammability disturbing radiation emission and immunity to surrounding electric disturbances FCC ID W45 03330 This dev...

Страница 4: ... to avoid obstacles and moving persons If possible place the Spy RF in central position regarding the Spy RF recorders Try to place them preferably at sight of each other On the wall it is preferable to them aside by using the special bracket ref 08512 of the catalog Place the antenna above the top the monitored unit fridge incubator oven cold rooms Never place the Spy RF horizontally If some diff...

Страница 5: ...C Storage range 40 85 C Radio range in free field 1km Radio band 868MHz or 902MHz Power supply 9 VDC 300 mA battery life 200 alarms or 2years Dimensions 123x69x30mm Protection degree IP34 EN 12 830 compliance Yes this device must be regularly checked according to EN 13 486 1 time per year recommended CE ERM compliance EN 301 489 EN 61000 EN 61010 EN 55022 EN 300 220 FCC compliance FCC part 15 Supp...

Страница 6: ...n N of concerned Spy RF AlarM Type Choose for what sort of alarm Target Monitoring units concerned Time delay Delai before alarm goes on After Ending the window will close and the Spy RF AlarM is installed and appear in the fleet Ajouter un appareil Choose the type of recorder Select the modem associated to the device Enter the serial n of the device End Select the device model ...

Страница 7: ...n Sirius to initialize it again 2 contact duration for each state in second 3 activation led and buzzer coefficient Take care changing this setting modifies the duration of battery life It is recommanded to program a planned task reading Spy RF Alarm configuration to check if it is already operational If the device do not answer to the Sirius request Sirius will send a technical alarm b Sending re...

Страница 8: ...formed by specialists That s why JRI has created maintenance contracts We bring you a global solution which makes your maintenance easier This overall service offer includes maintenance and also metrological services which ensure you that your system is fully performant You won t worry about your devices maintenance anymore With this maintenance contract you will benefit for a minimal period of 2 ...