background image

©JRI  

I.

 

INTRODUCTION 

Congratulations, you own a SPY RF Alarm ! This device allows to locally advertise with a remote alarm system in case of 
need or order. 

a)

 

Equipment 

 

1 Spy RF Alarm 

 

1 wall-mounting bracket 

 

1 adhesive plaster 

 

1 protection connector 

 

1 user manual 

 

b)

 

Symbols 

 

 

II.

 

 INSTALLATION RECOMMENDATIONS 

The Spy RF Alarm is an alarm device able to communicate wirelessly with the operating software SIRIUS.  

The wireless communication is based on radio frequency. As we are daily in contact with it (radio, TV…) it is easy to think 
that it always works. This is true if basic rules on the positioning of recorders are respected because wireless 

communication is subject to perturbations.  
 

a.

 

Perturbations sources 

 

Presence of obstacles in the way of the waves between the Spy RF ModeM and the Spy Rf (wall, ceiling, person, 
furniture…) or close to the antenna.  

 

Obstacles thickness in the way of the waves. The absorption is more important in diagonal as perpendicularly 

 

 
 

 
 

 

 

Waves cannot pass through full metallic walls. On the other hand, a perforated wall allows the waves passing with 

attenuation 

 

 

 

 

 

 
RECYCLING : do not throw in a rubbish dump or in a domestic waste container. Comply with the regulation to throw away the 
device. 

 

POWER SUPPLY : this device is powered by a continuous current delivered by a main power supply adaptor (230VAC). Comply to 
the security and utilization regulations of electric power. Use an electric installation complying with these regulations 

 

CE MARKING :this equipment is certified to comply with the European regulation for the electric security, inflammability, disturbing 
radiation emission and immunity to surrounding electric disturbances. 

 

FCC ID:W45 03330 
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not 
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause 
undesired operation 
In accordance with FCC requirements, changes or modifications not expressly approved by JRI could void the user's authority to 
operate this product. 
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the 
FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated 
in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used 
in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in 
a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own 
expense 

Содержание SPY RF AlarM

Страница 1: ...USER MANUAL Spy RF Alarm 06255D ...

Страница 2: ...s 3 III PRESENTATION 4 IV INSTALLATION 4 a Installation recommendations 4 b Installation of wall mounting bracket 4 c Activation 4 V BATTERY CHANGE 5 VI RESET 5 VII CHARACTERISTICS 5 VIII ADDING SPY RF ALARM IN SIRIUS 6 a Setting up 7 b Sending remote alarm 7 IX WARRANTY 8 X MAINTENANCE CONTRACT 8 XI ENVIRONMENT PROTECTION 8 ...

Страница 3: ...ivered by a main power supply adaptor 230VAC Comply to the security and utilization regulations of electric power Use an electric installation complying with these regulations CE MARKING this equipment is certified to comply with the European regulation for the electric security inflammability disturbing radiation emission and immunity to surrounding electric disturbances FCC ID W45 03330 This dev...

Страница 4: ... to avoid obstacles and moving persons If possible place the Spy RF in central position regarding the Spy RF recorders Try to place them preferably at sight of each other On the wall it is preferable to them aside by using the special bracket ref 08512 of the catalog Place the antenna above the top the monitored unit fridge incubator oven cold rooms Never place the Spy RF horizontally If some diff...

Страница 5: ...C Storage range 40 85 C Radio range in free field 1km Radio band 868MHz or 902MHz Power supply 9 VDC 300 mA battery life 200 alarms or 2years Dimensions 123x69x30mm Protection degree IP34 EN 12 830 compliance Yes this device must be regularly checked according to EN 13 486 1 time per year recommended CE ERM compliance EN 301 489 EN 61000 EN 61010 EN 55022 EN 300 220 FCC compliance FCC part 15 Supp...

Страница 6: ...n N of concerned Spy RF AlarM Type Choose for what sort of alarm Target Monitoring units concerned Time delay Delai before alarm goes on After Ending the window will close and the Spy RF AlarM is installed and appear in the fleet Ajouter un appareil Choose the type of recorder Select the modem associated to the device Enter the serial n of the device End Select the device model ...

Страница 7: ...n Sirius to initialize it again 2 contact duration for each state in second 3 activation led and buzzer coefficient Take care changing this setting modifies the duration of battery life It is recommanded to program a planned task reading Spy RF Alarm configuration to check if it is already operational If the device do not answer to the Sirius request Sirius will send a technical alarm b Sending re...

Страница 8: ...formed by specialists That s why JRI has created maintenance contracts We bring you a global solution which makes your maintenance easier This overall service offer includes maintenance and also metrological services which ensure you that your system is fully performant You won t worry about your devices maintenance anymore With this maintenance contract you will benefit for a minimal period of 2 ...

Отзывы: