e)

 

Password Management 

The password is used to identify a user. Each password is unique and assigned by Sirius 
when declaring users, and can not be used twice. This password allows users to identify 
themselves to perform actions such as alarm acknowledgment from the touchscreen Spy 
IP. The action will be authorized and stored by Sirius. 
The password change will just be made from Sirius. 
 
Default IP Spy has 1 Profile: 
Administrator: mdp 1111 
 

V.

 

HOW THE SPY IP WORKS 

The different channels of the recorder are completely independent. The functioning of the recorder 
depends  on  the  configuration  of  the  channels  which  is  carried  out  using  the  Sirius  software.  The 
main modules to be configured are: 

 

Start modes 

 

Off modes 

 

Logging interval 

 

Alarm management  
 

Содержание SPY IP 4

Страница 1: ...USER MANUAL SPY IP 10486F...

Страница 2: ...Start modes 10 c Zone 4 Alarm Thresholds 10 d Zone 5 Off Modes 10 e Main Menu 10 4 BACKLIGHT COLOURS 10 5 SCREEN NAVIGATION 11 a Main menu 11 b Menu Configuration 11 c Device Status Menu 12 d Alarm M...

Страница 3: ...omplies with current regulations CE MARKING this device complies with EU legislation for electric security inflammability disturbing radiation emission and immunity to surrounding electric disturbance...

Страница 4: ...guration information from the DHCP server If the UDP broadcast is not allowed you must carry out a manual installation on Sirius Storage using the IP address provided by the DHCP server and the serial...

Страница 5: ...twork UDP packets are never transmitted and you must carry out a manual installation If the manual installation fails make sure that the internal serial number matches the serial number printed on the...

Страница 6: ...3 Declare in Sirius measures RH on channels 2 and or 4 c Identification of the connectors d Wiring Rear view of the connectors Probe 1 to 4 Ethernet Network RJ45 Modular connector Male plug end on the...

Страница 7: ...JRI recommends using the cable with the reference number 00949 for connecting equipment which is not provided with a compatible socket f Battery backup Minimum battery backup time is 6 hours with a 3...

Страница 8: ...e alone Humidity Measurement range resolution accuracy probe alone 40 C to 85 C 0 01 C 0 2 C from 20 C to 50 C 0 4 C outside 0 100 0 01 2 from 20 to 80 3 5 outside Current input 0 20 ou 4 20 mA measur...

Страница 9: ...avoid damaging the touchscreen do not use sharp instruments and do not press hard 2 Touchscreen Description Channel ID Status of the device Measurement and start modes Channel number and alarm thresh...

Страница 10: ...resholds High Pre Alarm High Alarm Low Pre Alarm Low Alarm d Zone 5 Off Modes Push Button Programmed stop delay Target value upward movement Target value downward movement e Main Menu Back to previous...

Страница 11: ...r a pencil tip See Principle above Press the screen to access the main menu Back to measurement display a Main menu Select the desired zone by pressing the relevant icon b Menu Configuration The SPY I...

Страница 12: ...dgment from the touchscreen Spy IP The action will be authorized and stored by Sirius The password change will just be made from Sirius Default IP Spy has 1 Profile Administrator mdp 1111 V HOW THE SP...

Страница 13: ...mmed via Sirius are Immediate Pushbutton Programmed start delay Target value Change of state of one of the other channels a Immediate default mode in Sirius The channels set with this start mode will...

Страница 14: ...art recording when it has reached its target value taking into account the direction of the variation upward or downward movement If a channel has no target value it is considered as being configured...

Страница 15: ...t got the rights the request will be rejected and the channel will continue recording d Target value This off mode can only be used and configured channel by channel The channel will stop recording w...

Страница 16: ...re alarm then the backlight colour will be the same for all the channels according to the most important even In this case it will be RED The threshold alarms can be either instantaneous or continuous...

Страница 17: ...hout prior notice IX MAINTENANCE CONTRACT With our maintenance contract you will benefit for a minimal period of 2 years from the following advantages material verification once or twice a year warran...

Отзывы: