4-5
4
4-4 Test
This unit has the following test functions. Please refer section 3-6 “Test” for the details.
In this test, permitted distress signal for the test purpose is transmitted only by one burst.
Do not execute the test repeatedly in a short time frame.
Execute the test in 00 - 05 minutes of each o’clock for the reduction of processing capacity in the
satellite.
This test must not be performed as the Satellite EPIRB main unit remains removed from the
automatic release bracket. The distress signal may erroneously be emitted.
4-5 Parts for periodical replacement
This Satellite EPIRB has the following parts to be replaced periodically.
If the replacement period approaches, contact us or our dealer.
Table 4-5 Parts for periodical replacement
Parts to be replaced
Replacement period
(1) Battery replacement set
a) Battery
b) O-ring (2 kinds)
c) Protection seal
5 years after installation
(Described on the label)
(2) Hydraulic pressure sensor
2 years after installation
(Described on the hydraulic pressure sensor)
(3) Stopper pin
After manual activation
(Replace the exhausted battery together)
NOTE
Please note that the replacement time of the battery-replacement-set and the hydraulic pressure sensor is not
always corresponding.