3-6
3-6 Test
This unit has the following test functions. It is recommended to perform this test once a week at the condition
installed in bracket. Set the selector switch to “TEST” for performing this test. The selector switch can be
turned to “TEST” without releasing the stopper.
Fig.3-6 Position of the Selector switch when test is ongoing
Selector switch
position
Test contents
Satellite EPIRB status
Test result
Action
TEST
Check the
battery
voltage
*1
Yellow LED and orange
LED light for 4 sec.
The battery voltage is
normal.
-
Yellow LED and orange
LED blink for 4 sec. in 0.5
sec. interval.
The battery is
somewhat consumed.
Contact
purchased
dealer or JRC
Yellow LED and orange
LED blink for 4 sec. in
0.1sec. interval.
The battery is
exhausted.
Contact
purchased
dealer or JRC
Emission
check of
406.028MHz
Yellow LED and red LED
light for 0.44 sec.
406.028MHz
transmitter is normal.
-
Yellow LED lights for 0.44
sec.
(Red LED does not light.)
The signal is not
transmitted though
the SYNTH circuit
works.
Contact
purchased
dealer or JRC
LED does not light at all.
Malfunction of
the transmitter.
Contact
purchased
dealer or JRC
Check the
Indicator
lamp
Indicator lamp flashes at
2.6 sec. Interval.
The indicator lamp
is normal.
-
Indicator lamp does not
flash.
Malfunction of the
indicator lamp.
Contact
purchased
dealer or JRC
READY
- -
- -
Satellite EPIRB is in the normal status when results of above tests are normal.
Indicator lamp
Stopper pin
Stopper
Selector switch
Orange LED
Yellow LED
Red LED
Содержание JQE-103 -
Страница 2: ......
Страница 11: ...ix APPEARANCE Satellite EPIRB Fig 1 Satellite EPIRB Automatic release bracket Fig 2 Automatic release bracket ...
Страница 14: ......
Страница 21: ...1 5 1 1 3 3 Automatic release bracket Fig 1 3 3 Automatic release bracket Band ...
Страница 22: ......
Страница 50: ...5 4 ...
Страница 52: ......
Страница 53: ......