5-57
5.3.5.3. ALARM HISTORY
When
3.ALARM HISTORY
is selected from Maintenance Menu (5.3.5), ALARM HISTORY screen
appears.
This screen displays a history of alarms which occur while the
power is on. It displays the alarm history from the most recent one
maximum 20 lines. If the history consists of more than 20 lines, the
lines after 21st line will be displayed on the next screens.
If there is no more information to be displayed on the next screen,
[SCROLL] is not selectable. (
▼
does not appear either.)
If CLR key is pressed, the procedure goes back to “Maintenance
Menu.
Alarm History Screen
ALARM HISTORY UTC11:44
BRG : RNG
NAME / MMSI
270°: 0.18NM
35°: 0.29NM
* 22°: 0.92NM
OCEAN-LINE
QUEEN
ABCDEFG-MARU
1.04/05/21 12:31 035,A,A
no valid ROT information
2.04/05/21 12:31 032,A,A
Heading lost/invalid
3.04/05/21 12:31 030,A,A
no valid COG information
4.04/05/21 12:31 029,A,A
no valid SOG information
5.04/05/21 10:10 001,A,V
Not Transmitting Tx malf
unction
6.04/05/21 09:33 001,A,V
Antenna VSWR exceeds lim
▼
Alarm NO.
Text of the Alarm
The contents of unusual detection
001
Not Transmitting TX malfunction
Unusual detection at the transmission.
002
Antenna VSWR exceeds limit
Unusual detection of antenna output.
003
Rx channel 1 malfunction
Unusual detection of Rx channel 1.
004
Rx channel 2 malfunction
Unusual detection of Rx channel 2
005
Rx channel 70 malfunction
Unusual detection of DSC.
006
General failure
Detected a general failure
008
MKD connection lost
Detected the connection between AIS and
TRANSPONDER is lost.
025
External EPFS lost
No information of sensor position from outside.
026
No sensor position in use
No information of sensor position.
029
No valid SOG information
No information of SOG.
030
No valid COG information
No information of COG.
032
Heading lost/invalid
No information of HEADING.
035
No valid ROT information
No information of ROT.
051
TX power down
Detected TX power is down.
052
TX power supply error
Unusual detection of TX power supply.
053
Power supply error
Unusual detection of power supply.
055
Pa temp error
Detected the PA temperature is warming up.
056
TX power low
Detected the TX power is lower.
057
Vr error
Unusual detection of TX output.
060
TX pll unlock
Detected the TX PLL is unlocked.
061
Not TX
Detected the TX is not outputting.
062
Program Flash memory err
Unusual detection of check sum in the TOM with
CPU.
063
Data Flash memory err
Unusual detection of check sum in the other ROM.
064
MKD connection lost
No serial input from the transponder.(detected
by AIS)
065
SSD mismatch
Mismatch static information between transponder
and AIS.
Alarm Table
Содержание JHS-182 -
Страница 1: ...Automatic Identification System JHS 182 Instruction Manual 7ZPJD0226 ...
Страница 6: ...v External Views NTE 182 AIS Transponder NCM 779 AIS Controller ...
Страница 7: ...vi NQE 3182 Connection Box ...
Страница 8: ...vii NBD 577B Power Supply Unit NQD 4382 Junction Box ...
Страница 13: ...1 3 1 3 3 Configuration System Block Diagram ...
Страница 14: ...1 4 1 4 Outline Outline Drawing of NTE 182 AIS Transponder Unit mm Mass approx 2 6 kg ...
Страница 15: ...1 5 Outline Drawing of NCM 779 AIS Controller Unit mm Mass approx 1 0 kg ...
Страница 16: ...1 6 Outline Drawing of NQE 3182 Connection Box Unit mm Mass approx 2 5 kg ...
Страница 17: ...1 7 Outline Drawing of NBD 577B Power Supply Unit Unit mm Mass approx 3 8 kg ...